beautypg.com

Operation method, Program operation – Yamato Scientific DKN 912 Constant Temperature Drying Oven User Manual

Page 28

background image

24

Operation Method

Program Operation

This operation is used to change the temperature according to the setting temperature and time.

Program types

Six patterns of program types maximum can be input.

PrG1 -

1 program pattern using 30 steps maximum can be created.

PAt1

PrG2

PAt2

2 program patterns using 15 steps maximum can be created.

PAt1

PAt2

PrG3

PAt3

3 program patterns using 10 steps maximum can be created.

Before inputting program

Input program patterns before program operation.
① Check the number of steps in a created program and their setting temperature/time. Use the

program preparation sheet in pages 29 and 30 to check.

② Check the temperature rise/fall capability of the unit. Set the time within the capability above.

Suppose, for instance, that in the unit which has capability of increasing or decreasing
temperature by 50℃ within 30 minutes, about 30 minutes is needed to increase or decrease
temperature by 100℃ from current temperature

Repeat function:

Repeat function is useful in case the operation uses the program repeating the same program
steps. Refer to page28 for the function.

③ Check if the controller has sufficient free pattern for the number of steps to be created. The steps,

however, using the repeat function mentioned above are not counted.

Temperature fall/rise curve for DKN type

The temperature fall curve and temperature rise curve for DKN type are shown below.

The numeric value indicates the necessary time between temperatures (ex: about 15 minutes is
needed to increase temperature from 100℃ to 150℃ for DKN602). Temperature stability time
after reaching to the setting temperature is necessary to be added. Make sure to conduct a test

run before setting the optimum time.
Condition: room temperature 23℃, no load, exhaust opening fully opened (unit: minute)

DKN302 DKN402

DKN602/612

DKN812 DKN912

Rise Fall Rise Fall Rise Fall Rise Fall Rise Fall

260℃

20 - 20 - 25 - 20 - 25 -

200℃

15 20 20 20 20 20 15 20 25 30

150℃

10 15 15 20 15 20 10 25 20 30

100℃

10 20 15 30 15 30 10 40 20 60

50℃

5 45 5 60 5 75 5 120 5 180

Temp.

Time

△ Stop

△ Start