Maintenance, Nspection, Chedule – Wood’s Powr-Grip EO1DCB User Manual
Page 8

Rev 10.0/9-13
6
EO1DCB: #35191AFT
MAINTENANCE
WARNING: Always make sure battery is disconnected before servicing Back-Up
System.
I
NSPECTION
S
CHEDULE
Perform inspections routinely, according to the following frequency schedule:
Every-Lift Inspection
• Examine the DC Vacuum Back-Up System’s controls and indicators for visual damage.
• Test the battery for adequate charge (see B
ATTERY
T
EST
to follow).
If a battery’s charge appears to be inadequate, charge and retest the battery (see B
ATTERY
R
ECHARGE
to follow). If any other deficiency is detected during the inspection, correct it before
using the Back-Up System and perform the Frequent Inspection to follow.
Frequent Inspection
(
following every 20-40 hours’ use; or whenever Back-Up System is out of service for 1 month or more
)
• Examine the DC Vacuum Back-Up System (including fittings and hoses) for visual damage.
• Perform a vacuum test as directed in the lifter's instruction manual.
• Perform the B
ACK
-U
P
F
UNCTION
T
EST
to follow.
• Check for unusual vibrations or noises while the Back-Up System is operating.
If any deficiency is detected during the inspection, correct it before using the Back-Up System
and perform the Periodic Inspection to follow.
Periodic Inspection
(
following every 250-500 hours’ use; or whenever Back-Up System is out of service for 1 year or more
)
• Examine the entire DC Vacuum Back-Up System for external evidence of looseness,
deformation, cracks, excessive corrosion, dents in functional components, cuts, or any
deficiency which might constitute a hazard.
• Inspect all parts of the electrical system for damage, wear or contamination that could
constitute a hazard, in compliance with all local codes and regulatory standards that are
relevant for the geographical region.
CAUTION: Be sure to use appropriate cleaning methods for each type of electrical
component, as specified by codes and standards. Improper cleaning
can damage components.
• Keep a written record of all Periodic Inspections.
If any deficiency is detected during the inspection, correct it before using the lifter. If necessary,
return the Back-Up System to Wood’s Powr-Grip or an authorized dealer for repair (see LIMITED
WARRANTY).