1

FLEXR-HV11DC: #35037

SPECIFICATIONS

Description:

Designed for use with a crane or other hoisting equipment, the FLEXR-HV11DC

lifters employ vacuum to hold a load for lifting in the flat orientation.

Model Number:

FLEXR4HV11DC (w/4 Vacuum Pads)

FLEXR6HV11DC (w/6 Vacuum Pads)

Load Capacity:

(rated at 16" Hg [-54 kPa] on clean, smooth, nonporous flat surfaces

1

)

Per-Pad:

300 lbs [136 kg]

300 lbs [136 kg]

Maximum:

1200 lbs [545 kg]

1500 lbs [680 kg]

Lifter Weight:

184 lbs [84 kg]

204 lbs [93 kg]

Power Source:

12 volts DC, 26 amps

Battery Capacity:

26 amp-hours

Vacuum Pads:

2

10" [25 cm] nominal diameter, lipped (Model HV11), 55 standard rubber, spring-

mounted (¾" [20 mm] travel), with #60 filter screen

Pad Spread:

(to outer edges)

Maximum:

41" x 70¾" [1041 x 1797 mm]

Minimum:

23" x 54¼" [584 x 1378 mm]

Vacuum Pumps:

2 diaphragm type, 1 SCFM [28 liters/minute] nominal airflow

or

1 diaphragm type, 3 SCFM [85 liters/minute] nominal airflow

Vacuum Reserve Tank:

Vacuum reservoir helps prevent immediate vacuum loss in case of power failure

and extends battery life by reducing pump cycles required to maintain vacuum.

Vacuum Gauge:

Dial gauge indicates current vacuum level in positive inches of Hg and negative

kPa.

Low Vacuum Warning Light: Red light is energized until vacuum level is sufficient to lift maximum load

weight (higher than 16" Hg [-54 kPa]) and whenever vacuum loss causes pumps

to re-engage.

Options:

See separate instructions about optional features.

Operating Elevation:

Maximum = 7000 feet [2133 meters]

Operating Temperatures: 32° to 104° F [0° to 40° C]
Service Life:

This lifter is designed to have a service life of at least 20,000 lifting cycles, when

used and maintained as intended. Vacuum pads, filter elements and other wear-

out items are excluded; see MAINTENANCE and REPLACEMENT PARTS LIST for

more information. For the D

ISPOSAL OF THE

L

IFTER

after its service life, see

INTENDED USE.

ASME Standard BTH-1:

Design Category "B", Service Class "0" (see www.powrgrip.com for more

information)

Wiring Diagram:

The following wiring diagrams are attached for reference in servicing the lifter or

trouble-shooting a deficiency:

714E-W01 [E-W01]

,

714E-W02 [E-W02]

!!-CE-!! Note: This symbol appears in the

INSTRUCTIONS manual only when requirements of a CE Standard are different from

requirements of other standards that also apply to this vacuum lifter. CE requirements are mandatory in geographical areas
where CE Standards apply, but may be optional in other locations.

1

Load Capacity is based on a friction coefficient of 1; see MAINTENANCE: V

ACUUM

P

AD

M

AINTENANCE

: Friction Coefficient for

additional information.

2

Options include oil-resistant vacuum pads and pads with closed-cell foam rings for use on rough or textured surfaces.