8

FLEXR-HV11DC: #35037

T

O

C

HANGE THE

C

ONFIGURATION OF

V

ACUUM

P

ADS

The lifter can accommodate various load dimensions, depending on the position of the sliding

pad arms and movable pad mounts on the pad frame (see illustration in OPERATING FEATURES).
Move the pad arms and pad mounts inward or outward on the pad frame as needed to provide
adequate support across the load surface. The vacuum pads must be arranged symmetrically, to

keep the lifter balanced.

WARNING: Make sure all vacuum hoses are coiled or routed so they do not

become entangled, kinked or punctured.

To position a pad arm, use the pull ring to remove the cotterless

hitch pin from the arm’s sliding mount. While making sure the
vacuum hose does not get pinched, slide the arm to the desired

position and align the holes for the pin. Push the pin through the
holes until the retaining ball emerges on the far side of the arm
mount. On the opposite end of the pad frame, position the

second sliding pad arm at an equal distance from the center of
the lifter.
To position each set of vacuum pads on a pad arm,

remove the cotterless hitch pins from the pad mounts,

move the pads inward or outward equal distances on the
pad arm, and secure them with the cotterless hitch pins.
Before applying the vacuum pads to a load, make sure

that all vacuum hoses are properly connected and will
not interfere with lifter operation.

T

O

A

PPLY THE

P

ADS TO A

L

OAD

Powering up the Lifter

Make sure the lever on the vacuum control valve is in the center position (see T

O

R

ELEASE THE

P

ADS FROM THE

L

OAD

: About Energy Conservation Mode to follow). Place the power switch in the

"ON" position (blue indicator light remains illuminated while power is engaged).

4

The power

switch must remain in the "ON" position while operating the lifter.

5

WARNING: Never turn power off while operating lifter.

Placing the power switch in the "OFF" position during lifter operation could result in the release of
the load and possible injury to the operator (see T

O

L

IFT AND

M

OVE THE

L

OAD

: In Case of Power

Failure to follow).

4

After the power switch is placed in the "ON" position, the low vacuum warning light and the vacuum pumps turn on until the

lifter attains full vacuum. Since the lifter is operating in energy conservation mode at this stage, the pumps and warning light

may subsequently turn off. However, this does

not indicate that the lifter is ready to lift a load.

5

If a vacuum pump fails to function while the power switch is in the "ON" position, examine the circuit breaker (below power

switch) to determine whether it has interrupted the electrical circuit to the pump. Although the operator can reset the circuit

breaker, the power interruption may indicate an electrical problem that requires attention. Correct any deficiency before
resuming normal operation of the lifter (see wiring diagram provided).

COTTERLESS HITCH PIN

1 PULL RING

2 RETAINING BALL