beautypg.com

Acuum, Aintenance, Friction coefficient – Wood’s Powr-Grip MTCL6FS625DC User Manual

Page 29

background image

Rev 5.0/12-13

27

MTCL6FS625DC: #35078

Temperatures higher than 70° Fahrenheit [21° Celsius] require the battery to be charged more
frequently.
Identify the input voltage marked on the power system enclosure, plug the charger cord supplied

into the charger cord receptacle and plug the other end into an appropriate power source.

13

The

power source must be equipped with a ground fault circuit interrupter, in order to reduce the risk
of electrical shocks.

WARNING: Power source must be equipped with ground fault circuit interrupter.

Open the power system enclosure (see enclosure

latch in OPERATING FEATURES) and press the

charger's "MODE" button to select "NORMAL"
mode. After the mode has been selected, the
charger should begin to charge the battery

automatically. Lights #1-4 in the illustration
indicate the level of charging that has been
attained.

14

When the battery is fully charged, the

charger switches to a maintenance mode and

charging level light #4 (green) turns on. The blue
light on the battery gauge also turns on, to
indicate that the battery is fully charged. Be sure

to unplug the charger and check the battery
energy again before operating the lifter (see
B

ATTERY

T

EST

preceding).

When the lifter and its charger are used as
directed, the battery should take no more than 8

hours to charge completely.

15

However, following

long-term use, a battery gradually loses the
capacity to hold a charge. After reaching charging level #3, the charger analyzes the battery

voltage, to determine whether or not the battery is holding a charge. If the battery does not
hold a charge adequately, the charger's red error light (!) turns on, indicating that the battery
needs to be replaced (see REPLACEMENT PARTS LIST).

V

ACUUM

P

AD

M

AINTENANCE

Friction Coefficient

The friction coefficient represents the lifter's ability to resist load slippage when the load is

oriented in any position except horizontal. If the contact surfaces of either the load or the
vacuum pads are not clean, dry and in good condition, slippage is more likely to occur.

13

Any external power supply must conform to all applicable local codes.

14

If none of the charging level lights turns on, the battery connection or the battery itself may be faulty. If the red error light

(!) turns on immediately, the battery leads may be reversed or the charger terminals may be short-circuited; once the problem
has been corrected, the charger should function normally. The red error light can indicate other problems, depending on the

mode selected and level of charging; if necessary, contact Wood's Powr-Grip for assistance.

15

The charger is designed to automatically sense the energy level of the battery and reduce the charging rate when the battery

is fully charged. Accordingly, the charger does not need to be unplugged until the lifter is going to be used again.