Specifications – Wood’s Powr-Grip MTA8LP6FAC User Manual
Page 3

Rev 5.1/4-12
1
MTA8LP6FAC: #35095
SPECIFICATIONS
Model Number:
MTA8LP6FAC
Description:
Designed for use with a crane or other hoisting equipment, the MTA8LP6FAC lifter
employs vacuum to hold a load for lifting, and it provides mechanically assisted,
manual 90° tilt movements for load manipulation.
Power Source:
See serial number plate for specific AC voltage, frequency and amperage.
Vacuum Pads:
Eight 6" [15 cm] nominal diameter, low profile (Model LP6F), standard rubber, spring-
mounted (¼" [7 mm] travel), with #60 filter screen
Pad Spread:
Maximum
= 18¼" x 100½" [464 mm x 2556 mm]
(to outer edges)
Minimum
= 18¼" x 37½" [464 mm x 949 mm]
Load Capacity:
(rated at 16" Hg [-54 kPa] on clean, smooth, nonporous flat surfaces
1
)
Per-Pad
= 50 lbs [22.5 kg]
Maximum
= 360 lbs [165 kg]
Lifter Weight:
116 lbs [53 kg]
Tilt Capability:
Manual, 90°, with four-bar tilt linkage that minimizes operator effort and automatically
holds a correctly attached load in the upright or flat position
Vacuum Pump:
Rotary vane type, 2.5 SCFM [71 liters/minute] nominal airflow
Vacuum Reserve:
Vacuum reserve system helps prevent immediate vacuum loss in case of power
failure.
Vacuum Gauge:
Dial gauge indicates current vacuum level in positive inches of Hg and negative kPa.
Options:
Available
with Model CM3PE2 - 2" [5 cm] Pad Spacers. This option enables the lifter
to handle loads with surface obstructions, such as windows with mullions.
See separate instructions about other options.
Operating Elevation:
Maximum = 8000 feet [2438 meters]
Operating Temperatures: 32° to 104° F [0° to 40° C]
Service Life:
This lifter is designed to have a service life of at least 20,000 lifting cycles, when used
and maintained as intended. Vacuum pads, filter elements and other wear-out items
are excluded; see MAINTENANCE and REPLACEMENT PARTS LIST for more
information. For the D
ISPOSAL OF THE
L
IFTER
after its service life, see INTENDED USE.
ASME Standard BTH-1:
Design Category "B", Service Class "0" (see www.powrgrip.com for more information)
Wiring Diagram:
The following wiring diagrams are attached for reference in servicing the lifter or
trouble-shooting a deficiency: (120 VAC
(240 VAC);
!!-CE-!! Note: This symbol appears in the
INSTRUCTIONS
manual only when requirements of a CE Standard are
different
from requirements of other standards that also apply to this vacuum lifter. CE requirements are mandatory
in geographical areas where CE Standards apply, but may be optional in other locations.
1
Load Capacity is based on a friction coefficient of 1; see MAINTENANCE: V
ACUUM
P
AD
M
AINTENANCE
: Friction Coefficient for
additional information.