beautypg.com

Specifications – Wood’s Powr-Grip MTA6LP6FAIR User Manual

Page 3

background image

Rev 10.8/2-13

1

MTA4/6LP6FAIR: #35099

SPECIFICATIONS

Description:

Designed for use with a crane or other hoisting equipment, MTA4/6LP6FAIR lifters

employ vacuum to hold a load for lifting, and they provide mechanically assisted,

manual 90° tilt movements for load manipulation.

Model Number:

MTA4LP6FAIR (w/4 pads)

MTA6LP6FAIR (w/6 pads)

Lifter Weight:

48 lbs [22 kg]

55 lbs [25 kg]

Max. Load Capacity:

200 lbs [90 kg]

300 lbs [135 kg]

(based on Per-Pad Load Capacity of 50 lbs [22.5 kg], rated at 16" Hg [-54 kPa]

on clean, smooth, nonporous flat surfaces

1

)

Power Source:

Compressed air, 80-150 psi [550-1035 kPa] line pressure, 2 SCFM [57

liters/minute] @ 80 psi [550 kPa]

Vacuum Pads:

6" [15 cm] nominal diameter, low profile (Model LP6F), standard rubber, spring-

mounted (¼" [7 mm] travel), with #60 filter screen

Pad Spread:

Minimum

Maximum (to outer edges)

Length:

13" [327 mm]

39" [991 mm]

Width:

9" [226 mm]

30" [760 mm]

Tilt Capability:

Manual, 90°, with four-bar tilt linkage that minimizes operator effort and

automatically holds a correctly attached load in the upright or flat position

Vacuum Pump:

Venturi type, 1 SCFM [28 liters/minute] nominal vacuum flow @ 80 psi [550 kPa]

Vacuum Reserve:

Vacuum reserve system helps prevent immediate vacuum loss in case of power

failure.

Vacuum Gauge:

Dial gauge indicates current vacuum level in positive inches of Hg and negative

kPa.

Options:

Available

with Model CM3PE2 - 2" [5 cm] Pad Spacers. This option enables the

lifter to handle loads with surface obstructions, such as windows with mullions.
See separate instructions about other options.

Operating Elevation: Maximum = 13,000 feet [3962 meters]
Operating Temperatures: 0° to 120° F [-18° to 49° C]
Service Life:

This lifter is designed to have a service life of at least 20,000 lifting cycles, when

used and maintained as intended. Vacuum pads, filter elements and other wear-

out items are excluded; see MAINTENANCE and REPLACEMENT PARTS LIST for

more information. For the D

ISPOSAL OF THE

L

IFTER

after its service life, see

INTENDED USE.

ASME Standard BTH-1: Design Category "B", Service Class "0" (see www.powrgrip.com for more

information)

!!-CE-!! Note: This symbol appears in the

INSTRUCTIONS

manual only when requirements of a CE Standard are

different

from requirements of other standards that also apply to this vacuum lifter. CE requirements are mandatory

in geographical areas where CE Standards apply, but may be optional in other locations.

1

Load Capacity is based on a friction coefficient of 1; see MAINTENANCE: V

ACUUM

P

AD

M

AINTENANCE

: Friction Coefficient for

additional information.