beautypg.com

Wood’s Powr-Grip MR411LAC User Manual

Page 9

background image

Rev 22.0/12-13

7

MR4-AC: #35051

4) Connect the power cable from the lifter to the power source as follows: Wire the female

connector provided to an appropriate current-protected power source (see serial number

plate for power requirements).

WARNING: Wiring must be done by qualified personnel, taking all appropriate

safety precautions.

The power source must be equipped with a ground fault circuit interrupter, in order to reduce

the risk of electrical shocks.

WARNING: Power source must be equipped with ground fault circuit

interrupter.

Make certain the power cable is routed so that it does not become tangled while operating

the lifter or hoisting equipment. Then push the power cable’s male connector into the
female connector and twist to secure them together. Now the lifter is operational.

5) Perform Operational and Load Tests for the lifter as directed in MAINTENANCE: T

ESTING

S

CHEDULE

.