Specifications – Wood’s Powr-Grip MRPT1211LAC User Manual
Page 3
Rev 0.0/9-12
1
MRPT1211LAC: #35063
SPECIFICATIONS
Model Number:
MRPT1211LAC(O)
Description:
Designed for use with a crane or other hoisting equipment, the MRPT1211LAC(O) lifter
employs vacuum to hold a load for lifting, and it provides manual 360° rotation and
powered 90° tilt movements for load manipulation.
Power Source:
See serial number plate for specific AC voltage, frequency and amperage.
Vacuum Pads:
Twelve 11" [28 cm] nominal diameter, lipped (Model G3370), standard rubber, spring-
mounted (¼" [7 mm] travel), with #60 filter screen
Maximum Pad Spread:
MRPT1211LAC
MRPT1211LACO w/CF3TAO Option*
(to outer edges)
40" x 93" [1016 x 2362 mm]
40" x 120" [1016 mm x 3048 mm]
Lifter Weight:
472 lbs [214 kg]
535 lbs [243 kg]
Load Capacity:
(rated at 16" Hg [-54 kPa] on clean, smooth, nonporous flat surfaces
1
)
Per-Pad:
167 lbs [75.5 kg]
Maximum:
2000 lbs [905 kg]
Rotation Capability:
Manual, 360°, with automatic locking at each ¼ revolution (when desired)
Tilt Capability:
2
Powered, 90°; Speed = approx. 11 seconds; Duty = 58 tilts per hour
Vacuum Pump:
Diaphragm type, 3 SCFM [85 liters/minute] nominal airflow
or
Rotary vane type, 4 SCFM [113 liters/minute] nominal airflow
Vacuum Reserve Tank:
Vacuum reservoir helps prevent immediate vacuum loss in case of power failure.
Vacuum Gauge:
Dial gauge indicates current vacuum level in positive inches of Hg and negative kPa.
Vacuum Lift Light:
Green light is energized whenever vacuum level is sufficient for lifting maximum load
weight (higher than 16" [-54 kPa]).
Options:
*
Available
with Model CF3TAO Telescoping Pad Arms. This option enables a lifter to
handle loads with different dimensions from those of the standard pad frame.
See separate instructions about optional features.
Operating Elevation:
Maximum = 10,000 feet [3048 meters]
Operating Temperatures: 32° to 100° F [0° to 38° C]
Service Life:
This lifter is designed to have a service life of at least 20,000 lifting cycles, when used
and maintained as intended. Vacuum pads, filter elements and other wear-out items
are excluded; see MAINTENANCE and REPLACEMENT PARTS LIST for more
information. For the D
ISPOSAL OF THE
L
IFTER
after its service life, see INTENDED USE.
ASME Standard BTH-1:
Design Category "B", Service Class "0" (see www.powrgrip.com for more information)
Wiring Diagram:
The following wiring diagrams are attached for reference in servicing the lifter or
trouble-shooting a deficiency:
!!-CE-!! Note: This symbol appears in the
INSTRUCTIONS manual only when requirements of a CE Standard are different from
requirements of other standards that also apply to this vacuum lifter. CE requirements are mandatory in geographical areas
where CE Standards apply, but may be optional in other locations.
1
Load Capacity is based on a friction coefficient of 1; see MAINTENANCE: V
ACUUM
P
AD
M
AINTENANCE
: Friction Coefficient for
additional information.
2
Specifications shown for 120 V AC lifters; characteristics may vary for other voltages.