beautypg.com

Pply the, Ads to a, Powering up the lifter – Wood’s Powr-Grip MRTA811LDC User Manual

Page 14: Positioning the lifter on the load, Sealing the pads against the load

background image

Rev 9.0/6-12

12

MRTA8-DC: #35075

T

O

A

PPLY THE

P

ADS TO A

L

OAD

Powering up the Lifter

Make sure the lever on the vacuum control valve is in the center position (see T

O

R

ELEASE THE

P

ADS FROM THE

L

OAD

: About Energy Conservation Mode to follow). Place the power switch in the

"ON" position (blue indicator light remains illuminated while power is engaged).

6

The power

switch must remain in the "ON" position while operating the lifter.

WARNING: Never turn power off while operating lifter.

Placing the power switch in the "OFF" position during lifter operation could result in the release of

the load and possible injury to the operator (see T

O

L

IFT AND

M

OVE THE

L

OAD

: In Case of Power

Failure to follow).

Positioning the Lifter on the Load

Make certain that the contact surfaces of the load and all vacuum pads are free of any

contaminates that could prevent the pads from sealing against the load (see MAINTENANCE:
V

ACUUM

P

AD

M

AINTENANCE

).

Center the lifter’s pad frame to within 2" [5 cm] of the load center, since off-center loading can

cause the load to tilt or rotate unexpectedly (see T

O

L

IFT AND

M

OVE THE

L

OAD

: About the Tilt

Linkage and T

O

R

OTATE THE

L

OAD

E

DGEWISE

to follow), and it may also damage the lifter.

7

Make

sure that all vacuum pads will fit entirely on the load’s contact surface (see SPECIFICATIONS:

Pad Spread) and that they will be loaded evenly while lifting (see SPECIFICATIONS: Per-Pad Load
Capacity). Then position the lifter on the load so that all pads are touching the contact surface.

Sealing the Pads against the Load

Move the lever on the vacuum control valve to the “APPLY” position: Pull outward on the lever's

knob, move the lever all the way to the

right

and release it. This position opens the lifter’s

vacuum lines to the airflow created by the vacuum pump, causing air to be drawn immediately at
the vacuum pads.

8

Apply the lifter to the load until all pads seal against it.

WARNING: Keep valve lever in “APPLY” position throughout lift.

The valve lever must remain in the “APPLY” position throughout the entire lift. Any interruption

of the vacuum flow during lifter operation could result in the release of the load and possible
injury to the operator.
Note: If a vacuum pad has been lying against a hard object (as during shipping), it may be

slightly distorted. Although initially it may be difficult to apply the pad to a load, this condition
should correct itself with continued use.

6

After the power switch is placed in the "ON" position, the low vacuum warning light and the vacuum pump turn on until the

lifter attains full vacuum. Since the lifter is operating in energy conservation mode at this stage, the pump and warning light may
subsequently turn off. However, this does

not indicate that the lifter is ready to lift a load.

7

The lifter is designed to handle the maximum load weight (see SPECIFICATIONS: Maximum Load Capacity) when the load’s

center of gravity is positioned within 2" [5 cm] of the pad frame’s center point. Occasional loading deviations are permissible,
provided that the operator can maintain control of the load at all times and that the load weight is low enough to avoid damaging

the lifter.

8

To conserve battery energy and reduce the time required to apply the pads to a load, do not place the valve lever in the

“APPLY” position unless the vacuum pads are contacting the load.