beautypg.com

Water leakage around or under sill – Therma-Tru Doors Troubleshooting User Manual

Page 4

background image

Trouble Shooting

4.4

2014

SITE 4

Water Leakage Around or Under Sill

SITE 5 - Weatherstrip

Replacement

PROBLEM: Water leakage around or under sill.

Cause

Solution

Refer to…

Door not meeting weatherstrip

evenly when it closes, hitting

the top to bottom first.

Damaged or painted

weatherstrip.

Improper/insufficient sealant

and/or sealant breakdown

between sill and subfloor.

Broken seal where the sill

meets the jamb.

Sill humped or depressed

beyond range of door

bottom’s sealing capacity.

Humped sill.

Damaged sill saddle causing

door bottom bulb seal to

bunch up and wrinkle when

the unit closes.

Realign, reshim, readjust

lockside jamb so door

meets weatherstrip evenly

from top to bottom.
Replace weatherstrip.

Reseal under sill using

Elastomeric and Polyurethane

sealant.

Remove corner seal pad, pull

out weatherstrip at bottom, and

place a bead of Elastomeric and

Polyurethane sealant along

entire joint where jamb and sill

meet. Replace weatherstrip

and reapply corner seal pad.

Anchor sill to draw down

straight by drilling pilot

holes and securing with

galvanized screws.

Replace any wrinkled/torn

door bottom.
Shim jamb legs up to allow

sill to straighten. Reseal with

Elastomeric and Polyurethane

sealant under sill and anchor

sill in place.
Replace the saddle and

screw down.

SITE 1 - Pre-hung

Unit Installation

SITE 1 - Pre-hung

Unit Installation

SITE 1 - Pre-hung

Unit Installation

SITE 5 - Adjustable Sill

Threshold Replacement