beautypg.com

Installation, Wiring diagrams – Regency Panorama P33E Small Gas Fireplace User Manual

Page 52

background image

52

Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace

INSTALLATION

WIRING DIAGRAMS

This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will
continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation.

(Do not cut the ground terminal off under any circumstances.)

NOTE: Even if the fan is not purchased with the unit, it is still a good idea to bring power to the receptacle box (provided with the unit) in case the

fan is installed at a later date.

Proflame System
Configuration
886 GTMF
Wire Diagram

SureFire™ Switch

Proflame System
886 ON/OFF Stand Alone
Illustrated Wire Diagram

Surefire Switch
(IPI / CPI)

Standard Main ON/OFF
Switch or Optional Wall Switch

Battery Holder

Pilot Ground Wire

Chassis Ground

EI Pilot

Sense Electrode

Spark Electrode

DFC Wire Harness Assembly

Proflame DFC Board

886 Proflame Valve

Note: 4 AA batteries must be installed to operate
the burner switch.
Do not use a 9 volt battery.

IMPORTANT:

If the optional remote control is used, the AA batteries normally installed into the battery holder must be removed. The AA batteries in the

receiver now operate the unit. Having AA batteries in both the battery holder and receiver will damage the gas valve.