beautypg.com

Installation, Contemporary faceplate installation part 1, Derating to lower btu rating) – Regency Panorama P33E Small Gas Fireplace User Manual

Page 47

background image

Regency® P33E-4 Zero Clearance Direct Vent Gas Fireplace

47

INSTALLATION

Contemporary Faceplate Derating Kit Contains:
Qty. Part #

Description

1

904-434

Burner Orifi ce #47 (Natural Gas)

1 904-241 Burner Orifi ce #56 (Propane Gas)
(NOTE: Must also use Kit #434-969 with

P33 units and Kit #425-972 with P33E units)

1

918-777 Decal Overlay

1 918-767 Instruction

Sheet

Remove the 2 screws, push Burner

Assembly to the left and lift out.

1) Shut off the gas supply.

2) a) Open the fl ush door and remove the door (see p.37 in the P33-4 manual).

b) Remove the logs, embers, and brick panels (if used).

c) Remove the 2 screws holding the Burner Assembly to the fi rebox base.

Push the Burner Assembly to the left and lift out.

Burner Orifi ce

3) Remove burner orifi ce with a 1/2" wrench and discard. Use another wrench to hold on to the elbow behind the orifi ce.

4) Reinstall new burner orifi ce and tighten.
NG #47
*LP #56 (LP Conversion - Must also use Kit #434-969 with P33 units and Kit #425-972 with P33E units)

5) Reverse Steps 1 and 2.

Note: Place Decal Derating P33-4 (918-777) to decal plate by overlaying existing decal located on the front side base of the unit.

* For conversion from NG to LP refer to the NG to LP conversion section in the P33-4 manual.

CONTEMPORARY FACEPLATE INSTALLATION PART 1

(

DERATING TO LOWER BTU RATING)

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER

IF IN DOUBT DO NOT DO THIS CONVERSION !!