beautypg.com

Installation, Installation precautions, Safety precautions for the installer – Regency Ultimate U39 Medium Gas Stove User Manual

Page 15: Rigid pipe venting arrangements

background image

Regency

®

U39 ULTIMATE Direct Vent Freestanding Gas Stove

15

INSTALLATION

INSTALLATION

PRECAUTIONS

These venting systems are engineered
products that have been designed and
tested for use with the U39-NG1, and
U39-LP1. The warranty will be voided and
serious fi re, health or other safety hazards
may result from any of the following actions:

1) Installation of any damaged Direct Vent

component

2) Unauthorized

modifi cation of the Direct

Vent System

3) Installation of any component part not

manufactured or approved by Simpson
Dura-Vent or Fireplace Products
International Ltd.

4) Installation other than as instructed

by Simpson Dura-Vent and Fireplace
Products International Ltd.

Warning: Always maintain
required clearances (air spaces)
to nearby combustibles to
prevent a fi re hazard. Do not fi ll
air spaces with insulation.

Be sure to check the vent termination
clearance requirements from decks,
windows, soffi ts, gas regulators, air supply
inlets and public walkways as specifi ed
in the "Exterior Vent Terminal Locations"
section in your local building codes.

The gas appliance and vent system
must be vented directly to the outside
of the building, and never be attached
to a chimney serving a separate solid
fuel or gas-burning appliance.
Each
direct vent gas appliance must use it's
own separate vent system. Common vent
systems are prohibited.

SAFETY

PRECAUTIONS FOR

THE INSTALLER

1)

Wear gloves and safety glasses for
protection.

2)

Exercise extreme caution when using
ladders or on roof tops.

3)

Be aware of electrical wiring locations
in walls and ceilings.

RIGID PIPE VENTING ARRANGEMENTS

Vertical Termination Systems for

Residential Manufactured and

Mobile Homes

The shaded area in the diagram below shows all
allowable combinations of straight vertical and
offset to vertical runs with vertical terminations.

Maximum two 45

o

elbows.

If the vent is ENCLOSED in a chase (min. size 9" x
9") maintain a 1-1/4" clearance to combustibles.

May be installed in Manufactured (Mobile)

Homes after fi rst sale.

Horizontal Terminations for All

Venting Systems

The shaded areas in the diagram below show
all allowable combinations of vertical runs
with horizontal terminations. Maximum one
90

O

elbow (two 45

o

elbows equal one 90

o

elbow).

Propane and Natural Gas:

Residential, Manufactured and

Mobile Homes Installations

The venting arrangements diagrammed below,
have a min. of 75% (fl ue loss) effi ciency with Fan
Off, as required for manufactured homes. (Actual
effi ciency may be as high as 85%)

May be installed in Manufactured (Mobile)

Homes after fi rst sale.

Vent Restrictor Position

To set the Vent restriction as
indicated in the diagram, simply
loosen the screws and push the
vent restrictor plate to the correct
position. Tighten the screws.

Vent Restrictor setting at

38,000 Btu/h

Vent Restrictor setting at

30,000 Btu/h