INSTALLATION

1) Positive Flue

Connection

with Cleanout

2) Direct Flue

Connection

with Cleanout

3a) Full Flue Liner

(No Cleanout

Required)

Note: A clean-out door is sometimes

required, by your inspector, to be

installed when either the Positive flue

connection or Direct flue connection

method is used.

The use of one of the connection methods listed

on this page not only increases the safety of your

insert by directing the hot gases up the flue, but

will also help increase the unit's efficiency and

decrease creosote deposits in the chimney.

When a connected flue or liner is in use, the

insert is able to “breathe” better by allowing a

greater draft to be created. The greater draft can

decrease problems such as, difficult start-ups,

smoking out the door, and dirty glass.

INSTALLATION INTO A

FACTORY BUILT

FIREPLACE

1) When installed in a factory built fireplace, a

full stainless steel rigid or flexible flue liner

is mandatory, for both safety and perform-

ance purposes. When a flue or liner is in

use, the insert is able to breathe better by

allowing a greater draft to be created. The

greater draft can decrease problems such

as, difficult start-ups, smoking out the door,

and dirty glass.

2) In order to position the flue liner, the exist-

ing rain cap must be removed from your

chimney system. In most cases the flue

damper should also be removed to allow

passage of the liner.

3) In most cases opening the existing spark

screens fully should give enough room for

the insert installation. If it does not, remove

and store.

When referencing installation or connec-

tion to masonry fireplaces or chimneys, the

masonry construction must or shall be code

complying.

INSTALLATION INTO A

MASONRY FIREPLACE

The insert must be installed as per the require-

ments of your local inspection authority. Three

methods of flue connection are acceptable in

most areas, these include:

1) Positive flue connection, where a large

blocking plate and a short connector pipe

is used.

2) Direct flue connection, where a smaller

blocking plate and a connector pipe to the

first flue liner tile is used.

3) Full flue liner, where a stainless steel rigid

or flexible liner pipe is routed from the insert

outlet collar to the top of the chimney.

Hampton highly recommends the use of a full

liner as the safest installation and provides the

most optimum performance. Your retailer should

be able to help you decide which system would

be the best for your application.

In Canada this fireplace insert must be

installed with a continuous chimney liner

of 5.5" or 6" diameter extending from the

fireplace insert to the top of the chimney.

The chimney liner must conform to the

Class 3 requirements of CAN/ULC-S635

or CAN/ULC-S640, Standard for Lining

Systems for New Masonry Chimneys.

4) If the floor of your fireplace is below the

level of the fireplace opening, adjust the

insert's levelling bolts to accommodate the

difference. When additional shimming is

required, use non-combustible masonry or

steel shims.

5) Measure approximately the alignment of the

flue liner with the position of the smoke outlet

hole on the insert to check for possible offset.

If an offset is required, use the appropriate

offset adaptor in your installation.

6) Once the above items have been checked,

slide your insert into position after first po-

sitioning and securing the flue liner to the

offset adaptor.

Attach the rod to the adaptor and slide the

adaptor onto the unit as the unit is slid into

position. Ensure a positive connection.

Secure the adaptor to the unit by using 2

bolts, flat washers, lock washers and one

screw in the front.

Re-install raincap at completion of installa-

tion.

Installer: Please record unit serial number here before installing blower.

Serial No.______________________________