Installation, Clearances, Gas fireplace – Regency Excalibur P90 Medium Gas Fireplace User Manual

Page 10: Manufactured mobile home additional requirements

background image

10

Excalibur

®

P90 Zero Clearance Direct Vent Gas Fireplace

INSTALLATION

Side Wall Clearance

6-1/2" (165mm)

Horizontal Vent Clearances
Top

2-1/2"

(64mm)

Side

1-1/2"

(38mm)

Bottom

1-1/2"

(38mm)

Vertical Vent Clearances 1-1/4"

(32mm)

Alcove Clearances**:
Max.

Depth 36"

(914mm)

Min.

Width 48"

1219mm)

Min.

Height 72"

1829mm)

* see mantle clearance instructions
(Refer to the "Combustible Mantels" section).

CLEARANCES

The clearances listed below are Minimum
distances unless otherwise stated:

A major cause of chimney related fi res is
failure to maintain required clearances (air
space) to combustible materials. It is of the
greatest importance that this fi replace and
vent system be installed only in accordance
with these instructions.

GAS FIREPLACE

1) When selecting a location for your fi replace,

ensure that the clearances outlined on this
page are met.

2) P r o v i d e a d e q u a t e c l e a r a n c e s f o r

servicing.

3) The appliance must be installed on a fl at,

solid, continuous surface (e.g. wood, metal,
concrete). This may be the fl oor, or raised up
on a platform to enhance its visual impact.
If the appliance is going to be installed
on carpeting, combustible linoleum tile or
other combustible material other than wood
fl ooring, the appliance must be installed on
a metal or wood panel extending the full
width and depth of the appliance.

4) The P90 Direct Vent Gas Fireplace can

be installed in a recessed position or
framed out into the room as in A, B, C, D.

See Diagram 1.

A) Flat on Wall
B) Flat on Wall Corner
C) Recessed

into

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

1) Ensure that structural members are not cut

or weakened during installation.

2) Ensure proper grounding using the #8 ground

lug provided. See the "Wiring Diagram"
section.

used with a Listed Millivolt Thermostat. Some
areas may have further requirements, check
local codes before installation.

6) The P90 Direct Vent Gas Fireplace is

approved for alcove installations, which
meet the clearances listed on this page.

7) We recommend that you plan your instal-

lation on paper using exact measurements
for clearances and fl oor protection before
actually installing this appliance. Have a
qualifi ed inspector, dealer, or installer review
your plans before installation.

Note: For vent terminations see the

"Exterior Vent Termination

Locations"

section.

Diagram 1

Wall/Alcove
D) Corner

5) This appliance is

Listed for bedroom

installations when

HEATWAVE

DUCT SYSTEM

OPTIONAL KIT

#946-556

The HeatWave Air Duct Kit increases the
effectiveness of your fi replace by dispersing
warm air from the fi replace to remote locations in
the same room or other rooms in your home.

Up to two kits may be installed on the fi replace.
Please Note: Only 1 HeatWave kit may be
operated at one time. This includes the internal
blower option as well.

OPTIONAL

HEAT RELEASE KIT

#946-570

The Heat Release Kit expels warm air from
the fi replace to the outside of the building,
allowing the fi replace to be operated with less
heat entering the room. The kit may be used
on either the left or right side.

WARNING:

Fire hazard is an extreme risk

if these clearances are not

adhered to.

Clearances for HeatWave and

Heat Release Kit

Heat Release Kit

The HeatWave Duct Kit and the Heat Release
Kit have different clearance and framing
requirements, check the HeatWave and Heat
Release manual for details.

Min.

6-1/2"

(165mm)

Min. 18-1/4"

(464mm)

27-3/4"

(705mm)

To

p

of

Flange

Min.

44-1/4"

(1

124mm)

to

Ceiling"

Floor

36"

6"

(152mm)

Clearance to Combustibles from:
Back
0"

(0mm)

Side 0"

(0mm)

Floor 0"

(0mm)

NOTE: The minimum fl oor clearance must be
maintained from the top surface of the carpeting,
tile, etc.
See pg. 12 for Hearth Requirements.