1. Remove the top nuts on the junction

block studs.

2. Tighten the back nuts.
3. Install the three-wire cord and strain

relief provided on the cord set through
the hole in the power cord bracket.

4. Connect the red and black leads to the

outer terminals and the white lead to the
center terminal. Use the top nuts
removed earlier in step 1.

5. Push the cord upward (to relieve strain)

while tightening the strain relief clamp.

If local codes do not allow grounding
through the neutral, refer to the
illustration below of FOUR-WIRE
CORD CONNECTION.

120/240 or 240 VAC

1. Remove the top nuts on the junction

block studs.

2. Tighten the back nuts.
3. Remove the green ground screw and cut

off the ground strap as close to the
junction block as possible.

4. Remove the ground strap.
5. Install the four-wire cord and strain relief

provided on the cord set through the hole
in the power cord bracket.

6. Connect the red and black leads to the

outer terminals and the white lead to the
center terminal. Use the top nuts
removed earlier in step 1.

7. Connect the ground lead below the

junction block with the ground screw that
was removed earlier in step 3.

8. Push the cord upward (to relieve strain)

while tightening the strain relief clamp.

NOTE: A 4-conductor cord is to be used
when the appliance is installed in a mobile
home or when local codes do not permit
grounding through the neutral.

Effective January 1, 1996 the National
Electrical Code requires that new construction
(not existing) utilize a 4-conductor connection
to an electric range.

120/240 VAC

BLACK

WHITE IF
EQUIPPED

BLACK
LEAD

GROUND
STRAP
CUT AND
DISCARD

JUNCTION
BLOCK

RED

WHITE
LEAD

RED
LEAD

POWER CORD
BRACKET

STRAIN
RELIEF
CLAMP

STRAIN
RELIEF
CLAMP

BLACK

BLACK
LEAD

GROUND
STRAP

JUNCTION
BLOCK

RED

WHITE
LEAD

RED
LEAD

GROUND
LEAD

WHITE IF
EQUIPPED

THREE-WIRE CORD CONNECTION

FOUR-WIRE CORD CONNECTION

POWER CORD
BRACKET