SERVICE (cont.)

TANK HEATERS (Cont.)

17. Install tank assembly onto mounting brackets and

secure in place with four #8-32 nuts.

18. Install tank lid and secure in place with eight #8-32

nuts.

19. Connect the two white wires of the tank warmer

blanket.

20. Connect the limit thermostat to the front of the tank

assembly.

21. Connect the green wire to the tank mounting

bracket using #8-32 nut.

22. Connect the pink wire to the level probe.
23. Insert the temperature probe through the grom-

met in the tank lid and attach the black lead from
the clip to the sheath.

24. Install the elbow fitting of the vent hose into the

grommet in the tank lid.

25. If installing left tank, on brewers with faucet,

connect the outlet water line of the faucet to the
side of the tank and secure with clamp.

26. Connect the water supply tube from the solenoid

to the bottom of the tank and secure with clamp.

27. Connect the water supply tube from the dispense

valve to the side of the tank and secure with clamp.

28. Refer to FIG. 9 when reconnecting the tank heater

wires.

29. Install access panels and covers and refer to

Initial

Set-up

for refill and operation.

BLK to Control Board

RED to Terminal Block

FIG. 9 TANK HEATER WIRING

36672 030104