Minimum, Iep 4024, Heater mounting – Schwank IEP-4024 User Manual
Page 10: Table 2, Required clearances, Figure 2: minimum required clearances

10
IM110822
RD: AUGUST 2011
RL; 1A
BA
InfraSave IEP-4024 Manual
TABLE 2:
MINIMUM
REQUIRED CLEARANCES
IEP 4024
Above ‘A’
Inches [cm]
Floor ‘F’
Inches [cm]
Clearance ‘C’
Inches [cm]
4000 W, 230 - 240V, 60 Hz, 18 Amps
(9 Amps each of two branch circuits)
12” [30]
72” [180]
36” [90]
Spacing ‘D’
Inches [cm]
More than
36” [90]
Heater Mounting:
1. Mount the heater on a non-combustible surface or structural member, and maintain at
least all minimum clearances indicated in Table 2 and Figure 2 above.
2. Use the Mounting Brackets supplied with the heater - see Figure 3 next page.
3. Hardware to fasten the Mounting Bracket to the structure is field supplied by the installer
since the type of hardware fastening is determined by site conditions.
4. Each Mounting Bracket fastens to the wall using two (2) field supplied bolts or lag screws
through two holes in one side of the bracket. Mount brackets to the wall with a separation
distance of 35-
5
/
8
inches [90.5 cm] to fit the heater between the mounting extensions of
the brackets - see next page.
5. Fasten the Mounting Brackets ‘plumb’ and aligned level to each other (35-
5
/
8
inches [90.5
cm] between mounts) so that the heater is oriented horizontally on the long axis.
FIGURE 2: MINIMUM Required Clearances
continued ...
FASTEN BRACKETS TO STRUCTURAL MEMBER (OR
EQUIVALENT STRENGTH AND INTEGRITY) OF A NON-
COMBUSTIBLE WALL / SURFACE
LONG AXIS: HORIZONTAL
DO NOT PLACE ANYTHING CLOSER THAN 3 ft (90 cm)
(CLEARANCE ‘C’) IN FRONT OF OR BELOW THE HEATER