TABLE 3: MINIMUM CLEARANCES TO COMBUSTIBLE
7. MINIMUM CLEARANCES TO COMBUSTIBLES
The structure, materials, or items in proximity to, or stored under the
heater will be subjected to radiant heat and could be seriously damaged.
The clearances to combustible material represent the minimum dis-
tances that must be maintained between the outer heater surface and a
nearby surface so that a surface temperature of 90F°(50C°) above ambi-
ent is not exceeded.
It is the installer’s responsibility to ensure that building materials with a
low heat tolerance which may degrade at lower temperatures are pro-
tected to prevent degradation.
sportSchwank
Angle Mounted 1° to 30°
Horizontal
ABOVE
A
In. [cm]
REAR
R
In. [cm]
BELOW
B
In. [cm]
FRONT
F
In. [cm]
TOP
T
In. [cm]
SIDES
S
In. [cm]
UNDER
U
In. [cm]
10
24" [61] 8" [20] 66" [91] 66" [170] 18" [46] 30" [76]
90" [229]
15
24" [61] 8" [20] 66" [91] 66" [168] 18" [46] 30" [76]
96" [244]
20
24" [61] 8" [20] 70" [91] 70" [178] 18" [46] 36" [91] 100" [254]
30
24" [61] 8" [20] 74" [91] 74" [188] 18" [46] 42" [107] 105" [267]
FIGURE 4: MINIMUM CLEARANCES TO COMBUSTIBLE
R
A
F
B
T
S
U
S
Horizontal
Angle Mounted
1° to 30°