Robustel GoRugged M1000 Pro V2 Quick Guide
RT_QG_M1000 Pro V2_v.1.0.0
24.01.2014
2 / 6
1.3 Working Mode Switch
There are two working modes available in the gateway, please check carefully:
Mode
Description
Config Mode
When DIP switches to Config Mode, user could use follow functions:
1. Configure gateway via M1000 Pro V2 Configurator ;
2. Upgrade firmware.
Serial port parameters is fixed as 115200, 8, None, 1
Normal Mode
When DIP switches to Normal Mode, user could use follow functions:
1. Automatic GPRS/UMTS connection (no AT commands required);
2. Wakeup by Timing/Periodical/Call/SMS/Serial Data;
3. Transparent data communication or become a Modbus gateway;
4. CSD communication.
5. Remote configuration or firmware updating.
Serial port default parameters: 115200, 8, None, 1
1.4 PIN assignment
PIN assignment for modem’s DB9 female connector
PIN RS232
RS485 (2-wire)
1
Data+ (A)
2
RXD ->
3
TXD <-
4
5
GND
6
Data- (B)
7
RTS <-
8
CTS ->
9
Switch