Pattern depth, Pattern width (open / closed) – BEA BODYGUARD III GT 400 User Manual
Page 2
BUTTON
PARAMETER
VALUE
BUTTON
PARAMETER
VALUE
SENSITIVITY
Door Closed = 6
Door Open = 7
0 (min)
9 (max)
INTERFACE
New Style
Old Style (LO21, B, K,
P, S, U, LO-LINX, MC15)
1
2
AUTO LEARN
0 = 30 sec
9 = Infinite
0 (min)
9 (max)
SETUP / WAND
Door Closed = 1
Door Open = 2
Restore to Default
1
2
9
OUTPUT CONFIG.
NO
NC
1
2
HOLD TIME
0 = 0.5 sec
9 = 9 sec
0 (min)
9 (max)
IMMUNITY
Low (Normal)
Medium (Rain)
High (Snow) *
* - BGIII-C
1
2
3 *
FREQUENCY
Normal Mode; Low
Normal Mode; High
Quiet Mode; Low
Quiet Mode; High
1
2
3
4
SWING
ACT
COM
SAF
STALL
STALL COM
SWING
ACT
COM
SAF
STILL
STALL COM
Besam 300
13
12
11
15, 17
16, 18
HUNTER
ACT
RTN
SAF 1
SAF 2
RTN
Besam M/P
3
4
9
5
13
KM K
Green
White
Red
Yellow
White
DOM
Yellow
Grey
Blue
Purple
Grey
STANLEY L
Orange
Yellow
Red
Blue
Yellow
GT 300/400
Black
Red
White
White
Red
STANLEY M/P
2
1, 8
7
7
1, 8
GT MAG
6 Black
5 Red
4 White
3 Violet
5 Red
STANLEY 521
TB4-5
TB4-4
TB4-8
TB4-10
TB4-9
HORTON 4190
2
3, 6, 8
4
10
3, 6, 8
TORMAX TDA
2
1, 3, 6, 8
8 & 9
7
1, 3, 6, 8
Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please call BEA, Inc. If you must wait for the
following workday to call BEA., leave the door inoperable until satisfactory repairs can be made. Never sacrifice the safe operation of the automatic door or
gate for an incomplete solution. The following numbers can be called 24 hours a day, 7 days a week. For more information, visit www.beasensors.com.
US and Canada:
Canada:
Northeast:
1-866-249-7937
1-866-836-1863
1-866-836-1863
Southeast:
Midwest:
West:
1-800-407-4545
1-888-308-8843
1-888-419-2564
Page 2 of 2
75.5362.01 20090210
8 Door Control Connections
9 Company Contact
6 Sensing Zone Adjustment
7 Configurations
1
4
3
5
6
2
1ST ROW OF IR
THRESHOLD
2ND ROW OF IR
3RD ROW OF IR
4TH ROW OF IR
Pattern Depth
1: Deep (Threshold ON)
2: Medium (Threshold ON - OPEN)
3: Limited (Threshold ON)
4: Deep (Threshold OFF)
5: Medium (Threshold OFF - CLOSED)
6: Limited (Threshold OFF)
1
4
3
5
6
2
1ST ROW OF IR
THRESHOLD
2ND ROW OF IR
3RD ROW OF IR
4TH ROW OF IR
7
8
9
Pattern Width (Open / Closed)
1: Wide (CLOSED DOOR) 4: Asymmetric Right Narrow 7: Asymmetric Left Wide
2: Middle (OPEN DOOR) 5: Narrow Left
8: Asymmetric Right Wide
3: Asymmetric Left Narrow 6: Narrow Right
9: Center Narrow
NOTE
: When pattern width or depth is changed, a setup of the new pattern size will automatically be triggered
once a value key has been pressed.
Pattern Width, Depth & Sensitivity all
have independent door closed and
door open values.
ENSURE COMPLIANCE WITH ALL APPLICABLE CURRENT SAFETY STANDARDS (I.E. ANSI A156.10).