beautypg.com

Pattern depth, Pattern width (open / closed) – BEA BODYGUARD III GT 400 User Manual

Page 2

background image

BUTTON

PARAMETER

VALUE

BUTTON

PARAMETER

VALUE

SENSITIVITY

Door Closed = 6
Door Open = 7

0 (min)

9 (max)

INTERFACE

New Style

Old Style (LO21, B, K,
P, S, U, LO-LINX, MC15)

1
2

AUTO LEARN
0 = 30 sec

9 = Infinite

0 (min)

9 (max)

SETUP / WAND

Door Closed = 1

Door Open = 2

Restore to Default

1

2

9

OUTPUT CONFIG.
NO
NC

1

2

HOLD TIME
0 = 0.5 sec

9 = 9 sec

0 (min)

9 (max)

IMMUNITY

Low (Normal)
Medium (Rain)
High (Snow) *
* - BGIII-C

1

2

3 *

FREQUENCY

Normal Mode; Low
Normal Mode; High

Quiet Mode; Low

Quiet Mode; High

1

2

3
4

SWING

ACT

COM

SAF

STALL

STALL COM

SWING

ACT

COM

SAF

STILL

STALL COM

Besam 300

13

12

11

15, 17

16, 18

HUNTER

ACT

RTN

SAF 1

SAF 2

RTN

Besam M/P

3

4

9

5

13

KM K

Green

White

Red

Yellow

White

DOM

Yellow

Grey

Blue

Purple

Grey

STANLEY L

Orange

Yellow

Red

Blue

Yellow

GT 300/400

Black

Red

White

White

Red

STANLEY M/P

2

1, 8

7

7

1, 8

GT MAG

6 Black

5 Red

4 White

3 Violet

5 Red

STANLEY 521

TB4-5

TB4-4

TB4-8

TB4-10

TB4-9

HORTON 4190

2

3, 6, 8

4

10

3, 6, 8

TORMAX TDA

2

1, 3, 6, 8

8 & 9

7

1, 3, 6, 8

Do not leave problems unresolved. If a satisfactory solution cannot be achieved after troubleshooting a problem, please call BEA, Inc. If you must wait for the

following workday to call BEA., leave the door inoperable until satisfactory repairs can be made. Never sacrifice the safe operation of the automatic door or

gate for an incomplete solution. The following numbers can be called 24 hours a day, 7 days a week. For more information, visit www.beasensors.com.

US and Canada:

Canada:

Northeast:

1-866-249-7937
1-866-836-1863
1-866-836-1863

Southeast:

Midwest:

West:

1-800-407-4545
1-888-308-8843
1-888-419-2564

Page 2 of 2

75.5362.01 20090210

8 Door Control Connections

9 Company Contact

6 Sensing Zone Adjustment

7 Configurations

1

4

3
5

6

2

1ST ROW OF IR

THRESHOLD

2ND ROW OF IR

3RD ROW OF IR

4TH ROW OF IR

Pattern Depth

1: Deep (Threshold ON)

2: Medium (Threshold ON - OPEN)
3: Limited (Threshold ON)
4: Deep (Threshold OFF)

5: Medium (Threshold OFF - CLOSED)
6: Limited (Threshold OFF)

1

4

3

5

6

2

1ST ROW OF IR

THRESHOLD

2ND ROW OF IR

3RD ROW OF IR

4TH ROW OF IR

7

8

9

Pattern Width (Open / Closed)

1: Wide (CLOSED DOOR) 4: Asymmetric Right Narrow 7: Asymmetric Left Wide

2: Middle (OPEN DOOR) 5: Narrow Left

8: Asymmetric Right Wide

3: Asymmetric Left Narrow 6: Narrow Right

9: Center Narrow

NOTE

: When pattern width or depth is changed, a setup of the new pattern size will automatically be triggered

once a value key has been pressed.

Pattern Width, Depth & Sensitivity all
have independent door closed and
door open values.

ENSURE COMPLIANCE WITH ALL APPLICABLE CURRENT SAFETY STANDARDS (I.E. ANSI A156.10).

This manual is related to the following products: