Characteristics, 8 to 12-9, N 50 ω – Northern Connectors Radiall N Series Coaxial Connectors User Manual
Page 8: Characteristics electrical characteristics, Mechanical characteristics
www.radiall.com
12-8
N 50
Ω
CHARACTERISTICS
ELECTRICAL CHARACTERISTICS
Impedance
50Ω
Frequency range
DC - 11 GHz
Typical V.S.W.R. Frequency
straight models cable group: .085"
.141"
.250"
5/S+5/D
10/S+11/D
right angle models: 5/S+D
10/S+11/D
1 GHz
1.03
1.03
1.03
1.05
1.04
1.04
1.04
2.5 GHz
1.03
1.05
1.03
1.06
1.05
1.05
1.1
5 GHz
1.05
1.05
1.05
1.1
1.09
1.18
1.20
11 GHz
1.08
1.08
1.07
1.16
1.2
Intermodulation product (IMP
3
)
• Standard connectors
• Intermodulation connectors
• Home made intermodulation cable assemblies
- 90 dBm typ. (- 133 dBc typ. / 20W)
- 110 dBm typ. (- 153 dBc typ / 20W)
- 125 dBm typ. (- 165 dBc typ. / 20W)
Insertion loss straight connector
right-angle connector
MIL
< 0.15 dB max at 10 GHz ~ < 0.05 √F (GHz)
< 0.15 dB max at 10 GHz ~ < 0.1 √F (GHz)
RF Leakage
MIL
-90 dB min from 2 to 3 GHz (interface)
Insulation resistance
MIL
5000 MΩ min
Contact resistance
center contact
outer contact
MIL
Initial
1 mΩ
0.2 mΩ
After tests
1.5 mΩ
-
Working voltage in VRMS
at sea level
(at 70, 000 feet)
CECC
Cable 5/50: 850 (250)
Cable .085”/.141”:
350 (250)
Cable 10+11/50:
1400 (400)
Cable LMR 400/600:
1400 (400)
Cable .250”:
1400 (400)
Dielectric withstanding voltage in VRMS
at sea level
(at 70, 000 feet)
CECC
Cable 5/50: 1500 (350)
Cable .085”/.141”:
1000 (350)
Cable 10/50:
2500 (600)
Cable LMR 400/600:
2500 (600)
Cable .250”:
2500 (600)
RF testing voltage sea level
CECC
1500 VRMS (5 MHz sine wave)
MECHANICAL CHARACTERISTICS
Durability
CECC
500 matings
Engagement and separation torque
CECC
6.6 Ncm max (.58 Inch-pounds)
Recommended coupling nut torque
40 to 60 Ncm (manual)
130 Ncm (11.45 inch pounds) (with pliers R 282 202 000)
170 Ncm (14.96 inch pounds) (with torque wrench R 282 303 020)
Proof torque
CECC
170 Ncm (14.96 inch pounds)
Coupling nut retention force
CECC
450 N (101.25 Lbs)
Cable retention force
CECC
Cable 5/50/S
150 N (33.75 Lbs)
Cable 5/50/D
200 N (48 Lbs)
Cable 10/50
300 N (67.5 Lbs)
Cable 11/50
400 N (90 Lbs)
Cable .141”
270 N (60.75 Lbs)
Center contact retention force axial
MIL
27 N (6.08 Lbs) cables < 8 mm
68 N (15.30 Lbs) cables > 8 mm
Test/characteristics
Standard reference
Values/remarks
Standard packaging = 50 pieces.