Rectangular connectors gdm-series – Northern Connectors Hirschmann GDM-Series Valve Connectors (DIN 43650) User Manual
Page 41
204
RECTANGULAR CONNECTORS GDM-SERIES
Type A EN 175301-803 (DIN 43650) / ISO 4400 >
Cable socket with electronic insert
Order No.
Product description
Other standard types
Number of contacts
Cable gland
Conductor size
Standard
Housing Color
Construction type
Description of Wiring
LED color
Voltage rectifier
Suppressor
Other characteristics
Drawing
Technical data
Pin dimensions
Rated voltage
Rated current
Contact resistance
Type of termination
Suitable cables
Mounting
Material
Contact surface material
Contact bearer material
Housing material
Environmental conditions
Protection class (IEC 60529)
Pollution severity
Temperature range
Inflammability class
Housing
Contact bearer
Approvals
VDE
SEV
GL
Packing unit
Packaging unit
Scope of delivery and accessories
Accessories to order separately
Type
GDML 2016 LED 24 schwarz/black
GDML 2016 LED 24 YE black
934 412-002
function indicator (LED) with freewheeling diode
transparent housing,
cable gland grey:
Order no. 934 412-003
2 + PE
M 16 (black)
max. 1.5 mm2
DIN EN 175 301-803-A
transparent
A
LED red
LED-half-wave rectifier
1
2
(+)
(–)
(+)
(–)
RD
connection terminal
fork type spring
~
~
~
~
6.3 mm x 0.8 mm, 4.8 mm x 0.8 mm
AC/DC 24 V
8 A
≤ 4 mOhm
screw
4.5 mm to 10 mm diameter
central nut
Sn
PA
PA
IP 65 (gasket necessary)
3
-40 °C to +90 °C
94 HB
94 HB
50 pieces
GDM 3-7, Order no. 730 801-002;
GDM 3-21, Order no. 731 739-004;
GDM 3-16, Order no. 731 531-002;
GDM 3011-8, Order no. 732 574-001;
GDM 3011 RF-1, Order no. 734 363-001
934 413-002
function indicator (LED) with freewheeling diode
2 + PE
M 16 (black)
max. 1.5 mm2
DIN EN 175 301-803-A
transparent
A
LED yellow
LED-half-wave rectifier
1
2
(+)
(–)
(+)
(–)
YE
connection terminal
fork type spring
~
~
~
~
6.3 mm x 0.8 mm, 4.8 mm x 0.8 mm
AC/DC 24 V
8 A
≤ 4 mOhm
screw
4.5 mm to 10 mm diameter
central nut
Sn
PA
PA
IP 65 (gasket necessary)
3
-40 °C to +90 °C
94 HB
94 HB
50 pieces
GDM 3-7, Order no. 730 801-002;
GDM 3-21, Order no. 731 739-004;
GDM 3-16, Order no. 731 531-002;
GDM 3011-8, Order no. 732 574-001;
GDM 3011 RF-1, Order no. 734 363-001