Technical data, Ip67 filter d-sub connectors – Northern Connectors Conec IP67 D-Sub Filter Connectors User Manual
Page 4
5|3
Technical Data
Insulator
Contacts
Contact plating
Shell
Dielectric with standing voltage
Working voltage
Contact resistance
Insulation resistance
Current rating
Voltage surge 10 700µs
Temperature working range
Capacitor values
For other capacitance values please contact the factory.
Mating and unmating forces
Quality class
Degree of protection
Materials
Polyester GF UL94 V-0
CU alloy
Gold plated over nickel, solder area tin plated
Brass tin plated Stainless steel
Standard
424 VDC
Standard
300 VDC
100 VDC
100 VDC
Depending on isolation coordination (refer to DIN VDE 0110 IEC 664-1)
Max. 10 mΩ prior to stressing, Δ R max. 10 mΩ after stressing
per DIN 41652, Part 2
≥ 1GΩ
7.5 A (UL) 5 A (CSA, VDE)
3 A (UL, VDE) 2.5 A (CSA)
Standard
300 V
Standard
300 V
-25°C to +105°C
-25°C to +85°C
180 pF ± 20% tolerance
180 pF ± 20% tolerance
370 pF ± 20% tolerance
370 pF ± 20% tolerance
830 pF ± 20% tolerance
830 pF ± 20% tolerance
1300 pF ± 20% tolerance
9 pos. ≤ 30 N
15 pos.
≤ 50 N
15 pos. ≤ 50 N
26 pos.
≤ 84 N
25 pos. ≤ 83 N
44 pos.
≤ 120 N
37 pos. ≤ 123 N
62 pos.
≤ 170 N
50 pos. ≤ 167 N
A = Quality class 3 = 50 mating cycles
B = Quality class 2 = 200 mating cycles
C = Quality class 1 = 500 mating cycles
Requirement according to IEC 60529 – IP67
Filter D-SUB Standard
9, 15, 25, 37 and 50 position
Filter D-SUB High Density
15, 26, 44, and 62 position
Mechanical and electrical
characteristics
Technical alterations are subject to change without notice.