5. If starting a warm engine place the

choke lever

(Figure 23) in the "

OpEN " position.

Figure 23. Choke Lever (Open)

6. Grasp the starter grip (Figure 24) and slowly pull it out.

The resistance becomes the hardest at a certain

position, corresponding to the compression point. Pull

the starter grip briskly and smoothly for starting.

Figure 24. Starter Grip

7. If the engine has started, slowly return the choke lever

(Figure 25), to the

clOSEd position. If the engine has

not started repeat steps 1 through 6.

Figure 25. Choke Lever Closed

operation

8. Before the trowel is placed into operation, run the

engine for several minutes. Check for fuel leaks, and

noises that would associate with a loose guard ring

and/or covers.

Testing the centrifugal Safety Stop Switch

1. With the engine running at idle, place the safety stop

switch lever in the

"Off" position (Figure 26). Verify

that the engine shuts off. If the engine continues to run,

replace centrifugal safety stop switch.

Figure 26. Testing Safety Stop Switch

2.

Before performing this test, clear the area around the

trowel. Make sure it is free of debris and objects. Move

the safety stop switch lever to the

"ON" position, restart

the engine and let idle.

Stand behind the handle and spin the handle to the right,

simulating a runaway situation. (See Figure 27).

Centrifugal force should throw the safety switch outward

to the "

Off" position thus shutting off the engine.

Figure 27. Testing Safety Stop Switch

Runaway Situation

OFF

KE

EP CLEAR