PAGE 38 — HTX-SERIES • RIDE-ON POWER TROWEL — OPERATION MANUAL — REV. #2 (03/21/06)

)

Figure 41. Pressure Gauge (Hydraulic Pump)

Once the pressure gauges are installed and the spiders chained
together, the system can be checked.

With the foot pedal in the idle position and the engine at full
speed, the pressure should be 150 to 250 psi. If the pressure is
less than 150 psi, the charge system may need to be inspected
and/ or serviced. In particular, the suction filter and charge pump
relief valve should be checked. The suction filter may be plugged,
or the relief valve may be stuck. Either condition may cause low
charge pressure.

Many hydraulic problems are a result of low fluid levels. Before
checking any other possibilities, make sure the hydraulic fluid
level is up to the top of the sight glass which is located at the
back/center of the frame.

Hydrostatic pressure can be checked using a pressure gauge
with a range of at least 5,000 psi. Two male diagnostic quick
couplers (one for each pump) are located beneath the right grill
guard. To access couplers, (Figure 42), remove the grill guard. It
is best to use two gauges simultaneously (Figure 41), but it is
possible to use only one gauge and repeat the procedure for
each side.

HTX-SERIES — MAINTENANCE

With the engine at 50% to 70% of full speed, and spiders chained
together, slowly depress the foot pedal and read the gauges.
The pressure should get to at least 3,625 psi (250 bar). If the
pressure will not attain 3,625 psi (250 bar), the pump should be
inspected and/or serviced by an authorized service
representative.

3000

5000

bar

psi

4000

200

250

300

50

100

150

1000

2000

WIKA

3000

5000

bar

psi

4000

200

250

300

50

100

150

1000

2000

WIKA

1

1

2

3

4

1.

Pressure Guage - 5,000 PSI Range

2.

Parker Hannifin Quick Disconnect PD-Series Diagnostic Female Coupler

3.

Right Side Hydrostatic Pump Test Port

4.

Left Side Hydrostatic Pump Test Port

NEVER use your hand to find hydraulic
leaks. Use a piece of wood or cardboard.
Hydraulic fluid injected into the skin must
be treated by a knowledgable physician
immediately or severe injury or death can
occur.

Checking Hydraulic Pressure

To fully test the hydrostatic system, the spiders will need to be
locked so that they cannot rotate. This can be done by wrapping
a chain around an arm on each spider, thus chaining them
together in the back of the trowel.

WARNING

WARNING

WARNING

WARNING

WARNING