beautypg.com

Jto ride-on trowel — maintenance – Multiquip JTO User Manual

Page 31

background image

JTO RIDE-ON POWER TROWEL — OPERATION & PARTS MANUAL — REV. #5 (11/08/07) — PAGE 31

Trowel Arm Flatness Test

1. Using a piece of 3/4 inch thick steel plate or any surface which

is

true

and

flat

, check all

six sides

of each trowel arm for

flatness.

2. Check each of the six sides of the trowel arm (hex section

only) using a ten thousands of an inch (max.) feeler gauge
(Figure 25) between the flat of the trowel arm and an

ex

-

tremely flat

test surface.

3. If the trowel arm is found to be

uneven

or

bent

, replace the

trowel arm. A bent trowel will not allow the trowel to operate
in a smooth fluid rotation.

4. Next, check each of the six sides of the round machined shaft

section of the trowel arm. Each section should have the

same

clearance

between the round of the trowel arm shaft and the

test surface.

Figure 25. Trowel Arm Flatness Test

3. Should the trowel arm inserts (bronze bushing ) come out

with the trowel arm, remove the bushing from the trowel arm
and set aside in a safe place. If the bushing is retained inside
the spider plate, carefully remove the bushing.

4. Examine the bronze trowel arm bushing insert (Figure 23),

clean if necessary. Replace bushing if out-of-round or worn.

Figure 23. Bronze Bushings

Trowel Blade Removal

1. Remove the trowel blades from the trowel arm by removing

the three hex head bolts (Figure 24) from the trowel arm. Set
blades aside.

Figure 24. Trowel Blades

2.

Wire brush

any build-up of concrete from all six sides of the

trowel arm. Repeat this for the remaining three arms.

Trowel arms can be damaged by
rough handling or by striking
exposed plumbing or forms while in

operation.

ALWAYS look-out for

objects which might cause damage
to the trowel arms.

NOTE

JTO RIDE-ON TROWEL — MAINTENANCE