Digital control panel components, Primary screen, Secondary screens – Multiquip LS-600P User Manual
Page 27
MaYCO LS600p CONCReTe pUMp • OpeRaTiON MaNUaL — Rev. #0 (05/13/13) — page 27
DIGItAL cOntROL PAnEL cOMPOnEntS
pRiMaRY SCReeN
Screen 1
Indicates the various modes of the switch settings. Monitors
engine RPM - Idle speed 900, High speed 2350. Battery
charge indicator - Normal charge 13+ volts. Indicates
electrical malfunction - Refer to Troubleshooting section.
SECONDARY SCREENS
Screen 2
Displays the position of the
vOLUMe CONTROL switch
by indicating whether the increase or decrease position is
on or off.
Screen 3
Displays the number of hours the engine and pump
have been used and the number of faults the pump has
registered. All three indicators can be reset to zero by the
RESET switch on the control panel.
Screen 4
Displays the number of strokes the main hydraulic cylinders
have gone through. This indicator can be reset to zero by
the
RESET switch on the control panel.
LS 600 OFF
0000 ENG RPM
BATTERY 12.5 V
LOW OIL PSI
1
INDICATES
STATUS OF PUMP
( ON OR OFF)
INDICATES
ENGINE RPM
INDICATES
BATTERY
CHARGE
INDICATES
ELECTRIC
MALFUNCTION
FLOW DEC OFF
FLOW INC ON
2
INDICATES VOLUME
SWITCH IS NOT IN
THE - POSITION
INDICATES VOLUME
SWITCH IS IN THE
+ POSITION
E HRS: 00000.0
PMP HRS: 00000.0
FAULTS: 00000000
RESET TO CLEAR
3
INDICATES NO.
OF HOURS
ENGINE HAS
BEEN USED
MESSAGE OR
INSTRUCTION
INDICATES NO.
OF HOURS
PUMP HAS
BEEN USED
INDICATES NO.
OF FAULTS
DETECTED
STROKE CTR: 0000
PRESS RESET TO
ZERO STROKE CTR
4
INDICATES A
RUNNING
COUNT OF
NO. OF STROKES
MESSAGE OR
INFORMATION
Screen 5
Displays the ON/OFF electrical signal status of the various
12 volt solenoids (Swing A circuit, Main A circuit, Main B
circuit).
Screen 6
Displays the ON/OFF electrical signal status for the
Proximity Switch A, Proximity Switch B, Engine Fuel
Solenoid, and Unloader Solenoid.
Screen 7
Displays the number of times the main hydraulic cylinders
stroke and the yards per hour output. This indicator can
be reset to zero by the RESET switch on the control panel
Screen 8
Displays the electrical status of the engine fuel solenoid. To
test the 12-Volt solenoid status, activate with the
RESET
switch on the control panel.
Screen 9
Displays the communication status of the (optional) radio
remote control. To activate a new remote control connection,
use the reset switch on the control panel.
INDICATES
SWING A
CIRCUIT IS OFF
INDICATES
MAIN A
CIRCUIT IS OFF
INDICATES
MAIN B
CIRCUIT IS OFF
SWING A OFF
MAIN A OFF
MAIN B OFF
5
INDICATES
PROXIMITY A
CIRCUIT IS OFF
INDICATES
PROXIMITY B
CIRCUIT IS ON
INDICATES
FUEL SOLENOID
CIRCUIT IS OFF
INDICATES
UNLOADER
CIRCUIT IS OFF
PROX A OFF
PROX B ON
FUEL SOL OFF
UNLOADER OFF
6
INDICATES
THROTTLE
IS ON
INDICATES THE
NUMBER OF
STROKES
INDICATES THE
NO. OF STROKES
PER MINUTE
INDICATES THE
NO. OF YARDS
PER HOUR
THROTTLE ON
STROKES: 20
STROKES/MIN 8.2
YDS/HR 10.7
7
INSTRUCTION
OR MESSAGE
INDICATES THE
FUEL SOLENOID
IS OFF
TO TEST FUEL
SOL PRESS RESET
FUEL SOL OFF
8
INDICATES
THAT RADIO
REMOTE IS ON
INSTRUCTION
OR MESSAGE
RADIO ADDRESS
COMMUNICATING
PRESS RESET TO
LEARN A NEW ONE
9