MQ-D305/D306 SERIES DIAPHRAGM PUMP S— PARTS MANUAL— REV. #2 (08/24/05) — PAGE 19

MQ-D305/D306 SERIES — INITIAL START-UP (ENGINE)

8. Before the pump is placed into operation, run the engine for

several minutes. Check for fuel leaks, and noises that would
associate with a lose component.

9. To begin pumping, place the throttle lever (Figure 15) in the

"RUN" position.

Figure 14. Choke Lever (Closed)

Figure 15. Throttle Lever (Run)

Stopping The Engine

Normal Shutdown

1. Move the throttle lever to the IDLE position (Figure 16) and

run the engine for three minutes at low speed.

Figure 16. Throttle Lever (Idle)

2. After the engine

cools

, turn the engine ON/OFF switch to the

OFF” position (Figure 17).

3. Place the

fuel shut-off lever

(Figure 18) in the ”OFF

position.

Figure 17. Engine ON/OFF Switch (OFF)

Figure 18. Fuel Valve Lever (OFF)

Emergency Showdown

1. Move the throttle lever quickly to the

IDLE

position, and

place the engine ON/OFF switch in the “OFF” position.

NOTE

Pump speed can be

regulated

with

the engine throttle control from full
volume, 65 strokes per minute, to
about 40 strokes per minute for
lesser volume. Smoothest operation

can be determined by trying to pump at several speeds. Limit
maximum speed to 65 strokes per minute of the diaphragm (2,800
RPM engine speed).

7. If the engine has started, slowly return the choke lever

(Figure 14 ) to the “CLOSED position. If the engine has not
started repeat steps 1 through 6.