Inspection – Multiquip MVH150VGH User Manual
Page 17

MVH150VGH • OPERATION AND PARTS MANUAL — REV. #1 (09/22/08) — PAGE 17
INSPECTION
HYDRAULIC OIL CHECK
1. With handle bar positioned vertically (storage position),
remove the breather cap (Figure 7) from the breather
plug.
2. Use a 24 mm wrench and remove breather plug
(Figure 7). Visually check to see if hydraulic oil comes
up to the oil level line that is etched on the back side
of the handle.
3. If the hydraulic oil level is low, replace with "Shell
Tellus" oil #46 or equivalent.
V-BELT CHECK
OIL LEVEL
CAP
BREATHER
PLUG
HAND PUMP
Figure 7. Hydraulic Oil Check
CAUTION
Never attempt to check the V-belt with the engine running.
Severe injury can occur if your hand (Figure 8) gets
caught between the V-belt and clutch. Always use safety
gloves.
CLUTCH
PULLEY
VIBRATOR
PULLEY
Figure 8. V-Belt Hazard
1. To check the V-belt tension (Figure 9), remove
upper
belt cover.
2. The V-belt tension is proper if the V-belt bends 10 to 15
mm (Figure 10) when depressed with finger at midway
between the clutch and vibration pulley shafts.
3. A loose V-belt will decrease the power transmission
output, causing reduced compaction and premature
wear of the belt. V-belt in use is RPF-3320 (A-32 is
also usable).
4. If the V-belt becomes worn or loose, replace it by using
V-belt part number RPF-3320 or A-32.
Figure 9. V-Belt Location
Figure 10. V-Belt Tension