Viii. instructions for changing your filter – Purenex Multipure Aquaversa User Manual
Page 10

INSTRUCTIONS - STAINLESS STEEL MODELS
1. remove plastic wrapper and instruction wrap.
2. It may be advisable to place a pan beneath the housing before opening it.
3. Confirm that water is off. shut off diverter valve by pushing inward on the stem.
4. Go to Item #7 to continue the instructions for the countertop models.
5. Open drinking water faucet to relieve pressure.
6. remove Drinking water system (unit) from bracket (if mounted) by tilting the top
of the unit towards the wall and slide locking V-band of unit up and into upper
notch; slide unit out of bracket. (see Fig. B)
7. with the housing in an upright position, open the unit by unscrewing the black
knob on the locking V-Band, and spread it apart and remove the locking V-Band.
(see Fig. C)
8. separate the unit, leaving the black O-ring in Place.
9. remove the old filter (cartridge) from the unit housing by turning the cartridge in
the direction shown in Fig D.
10. wrap the used filter in paper and dispose of in your normal refuse.
11. Clean and rinse out the inside of the housing.
12. Inspect the rubber cushion; it is recommended that the cushion be replaced
every two to three years. To order a replacement part, request product code no.
MC252 (see Fig. D). The new MC252 is black.
13. screw new filter (cartridge) in the housing top by turning the cartridge as shown in
Fig e until firm; however, DO nOT OVer TIGHTen.
14. reconnect the housing top with bottom and replace locking V-Band; replace
black knob and turn until tight.
15. Be sure that the locking V-Band is fastened tightly by:
a. Check the V-Band to confirm that it is secured evenly around the housing top
and bottom.
b. Hand-tighten the black knob on the V-Band until it is as tight as possible.
16. Turn on water going to the Drinking water system (unit) and start the flow of water
through the unit.
17. allow water to run through the unit spout/faucet for about 5 minutes (10 minutes
for MP880sC) so that all air can escape.
18. Then turn off the water to the spout/faucet.
19. Check all connections to confirm that there are no leaks.
20. Flush the filter and charge the carbon by allowing water to run to waste for about
twenty 20 minutes (30 minutes for MP880sC).
21. shut off the flow of water through the Drinking water system.
22. Check for leaks.
VIII. Instructions for Changing Your Filter
Fig. D
Fig. a
Fig. C
Fig. e
Fig. B
10
turn to
remove
turn to
connect
Not applicable
Not applicable