beautypg.com

Troubleshooting, Outdoor lp gas barbecue grill model no. nsg3902d – Blue Rhino NSG3902D User Manual

Page 8

background image

Outdoor LP Gas Barbecue Grill Model No. NSG3902D

Troubleshooting

Problem

Possible Cause

Prevention/Cure

Burner will not light using ignitor

Wires or electrode covered with cooking residue.

Clean wire and/or electrode with rubbing alcohol.

Electrode and burners are wet.

Wipe dry with cloth.

Electrode cracked or broken - sparks at crack.

Replace electrode.

Wire loose or disconnected.

Reconnect wire or replace electrode/wire assembly

Wire is shorting (sparking) between ignitor and electrode.

Replace ignitor wire/electrode assembly

Bad ignitor.

Replace ignitor

Burner will not light with match

No gas flow.

Check if LP cylinder is empty. If LP cylinder is not empty, refer
to “Sudden drop in gas flow (reduced flame height). If empty,
replace or refill.

Coupling nut and regulator not fully connected.

Turning the coupling nut about one-half to three quarters
additional turn until solid stop. Tighten by hand only-do not use
tools.

Obstruction of gas flow.

Clear burner tubes. Check for bent or kinked hose.

Disengagement of burner to valve.

Reengage burner and valve.

Spider webs or insect nest in venturi.

Clean venturi.

Burner ports clogged or blocked.

Clean burner ports.

Sudden drop in gas flow or reduced flame height

Out of gas.

Check for gas in the LP cylinder

Excess flow safety device may have been activated.

Turn off knobs, wait 30 seconds and light grill. If flames are still
too low Reset the excessive flow safety device by turning off
knobs and LP cylinder valve. Disconnect regulator. Turn burner
control knobs to HIGH. Wait 1 minute. Turn burner control knobs
off. Reconnect regulator and leak check connections. Turn LP
cylinder valve on slowly, wait 30 seconds and then light grill.

Irregular flame pattern, flame does not run the full length
of burner.

Burner ports are clogged or blocked.

Clean burner ports.

Flame is yellow or orange.

New burner may have residual manufacturing oils.

Burn grill for 15 minutes with the lid closed

Spider webs or insect nest in venturi

Clean venturi.

Food residue, grease or seasoning salt on burner.

Clean burner.

Poor alignment of valve to burner venturi.

Assure burner venturi is properly engaged with valve

Flame blow out

High or gusting winds

Turn front of grill to face wind or increase flame height to HIGH
setting

Low on LP Gas

Replace or refill LP cylinder

Excess flow valve tripped

Refer to “Sudden drop in gas flow”

Flare-up

Grease buildup.

Clean grill.

Excess fat in meat.

Trim fat from meat before grilling.

Excessive cooking temperature.

Adjust (lower) temperature accordingly.

Persistent grease fire.

Grease trapped by food buildup around burner system

Turn knobs to OFF. Turn gas off at LP cylinder. Leave lid in
closed position and let fire burn out. After grill cools, remove
and clean all parts.

Flashback (fire in burner tube(s))

Burner and/or burner tubes are blocked

Clean burner and/or burner tubes

Inside of lid is peeling-like paint peeling

The lid is stainless steel, not paint.

Baked on grease buildup has turned to carbon and is flaking
off. Clean thoroughly.