MBT Lighting FLEXIPAR User Manual
Page 2
USER MANUAL FLEXIPAR
2/2
expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a
skilled person once a year.
Procedure:
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE,
including (but not
limited
to) calculating working load limits, installation material being used, and periodic safety inspection of
allinstallation material and the projector. If you lack these qualifications, do not attempt the installation
yourself, but instead use a professional structural rigger. Improper installation can result in bodily injury
and.or damage to property.
The projector has to be installed out of the reach of people.
If the projector shall be lowered from the ceiling or high joists, professional trussing systems have to be
used. The projector must never be fixed swinging freely in the room.
Before rigging make sure that the installation area can hold a minimum point load of 10 times the
projector's weight.
Mount the projector with the mounting-bracket to your trussing system using an appropriate clamp. The
hole in the mounting bracket has a diameter of 10 mm.
For overhead use, always install a safety-rope that can hold at least 12 times the weight of the fixture. You
must only use safety-ropes with quick link with screw cap. Pull the safety-rope through the hole on the
back of the device and over the trussing system or a safe fixation spot. Insert the end in the carabine and
tighten the safety screw.
The maximum drop distance must never exceed 20 cm.
A safety rope which already hold the strain of a crash or which is defective must not be used again.
Adjust the desired inclination-angle via the mounting-bracket and tighten the fixation screws.
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must
not be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling,
suspension, trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The objective lens will require weekly cleaning as smoke-fluid tends to building up residues, reducing the
light-output very quickly.
The interior of the device should be cleaned at least annually using a vacuum-cleaner or an air-jet.
There are no serviceable parts inside the device except for the lamp. Maintenance and service operations
are only to be carried out by authorized dealers.
Please refer to the instructions under "Installing/Replacing the lamps".
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by authorized dealers
only in order to avoid hazards.
Should you have further questions, please contact your dealer
.