Third party control setup, Ip address setup via web browser – Intelix FLX-1616 v1.6.4 User Manual
Page 18
FLX-1616 Installation Guide
18
Third Party Control Setup
IP Address Setup via Web Browser
Configuring the TCP/IP port is done via a web browser interface. A crossover cable is required for the
initial setup. The default IP address is printed on a sticker on the side of the FLX-1616.
1. Configure the computer to use the same network prefix as the IP address assigned to the matrix.
For example, the IP address of the matrix is 192.168.0.178. Set the computer to use a static IP
address within the same network range, such as 192.168.0.42.
2. Connect the crossover cable to the computer and to the TCP/IP port on the FLX-1616.
3. Open up Internet Explorer (Firefox, Chrome, and Safari crop the configuration options).
4. Go to the IP address printed on the sticker, which will take you to the Login screen.
5. The Default password is “88888”.