IPv6 Routing
• RFc 2080 RIPng for IPv6
• RFc 2740 oSPFv3 for IPv6
• IEtF draft_ietf_isis_IPv6 IS-IS for IPv6
• RFc 2545 Use of MP-BGP-4 for IPv6
IPv6 Multicast
• RFc 2362 PIM-SM
• RFc 2710 Multicast Listener discovery (MLd) for IPv6
• RFc 3306 Unicast-Prefix-based IPv6 Multicast
Addresses
• RFc 3810 MLdv2
• RFc 4602 PIM-SM (Partial address)
• draft-holbrook-idmr-igmpv3-ssm—IGMPv3 & MdLV2
for SSM
• draft-ietf-ssm-arch SSM for IP
IPv6 Transitioning
• RFc 2893 transition Mechanisms for IPv6 Hosts
and Routers
• RFc 3056 connection of IPv6 domains via IPv4 clouds
network management
• IronView Network Manager (INM) Web-based graphical user interface
• Integrated Standard-based Command Line Interface (CLI)
• RFc 3176 sFlow
• RFc 854 telnet
• RFc 2068 HttP
• RFc 2578 and 3410 SNMPv2 and v3
• RFc 1757 RMoN Group partial 1, full 2, 3, and 9
• HP openView for Sun Solaris, HP-UX, IBM’s aIX, Linux and Windows Nt
• SNMP MIB II
element security options
• AAA
• RADIUS
• Secure Shell (SSH v2)
• Secure Copy (SCP)
• tacacS/tacacS+
• Username/Password (challenge and Response)
• Bi-level access Mode (Standard and EXEc Level)
• Protection for denial of Service attacks, such as tcP SYN or Smurf attacks
environmental
• operating temperature: 0° c to 40° c (32° F to 104° F)
• Relative Humidity: 5 to 90% at 40° c (104° F), non-condensing
• operating altitude: 10,000 ft (3,000 m)
• Storage temperature: -25º c to 70º c (-13º F to 158° F)
• Storage Humidity: 95% maximum relative humidity, non-condensing
• Storage altitude: 15,000 ft (4,500 m) maximum
safety agency approvals
• caN/cSa-c22.2 No.60950-00/UL 60950—third Edition, Safety of
Information technology Equipment
• EN 60825-1 Safety of Laser Products—Part 1: Equipment classification,
Requirements and User’s Guide
• EN 60825-2 Safety of Laser Products—Part 2: Safety of optical Fibre
Communication Systems
• EN 60950 Safety of Information technology Equipment
Electromagnetic Emission Certification
• cSa 950 Electromagnetic Emission certification
• FCC Class A
• EN 55022/cISPR-22 class a/ VccI class a
• IcES-003 Electromagnetic Emission
immunity
• EN 61000-3-2 Power Line Harmonics
• EN 61000-4-2 ESd
• EN 61000-4-3 Radiated Immunity
• EN 61000-4-4 EFt
• EN 61000-4-5 Surge
• EN 61000-4-6 Low Frequency common Immunity
• EN 61000-4-11 Voltage dips and Sags Generic: EN50082-1
• ESd: IEc 61000-4-2; 4 kV cd, 8 kV ad
• Radiated: IEc 61000-4-3;3 V/m
• EFt/Burst: IEc 61000-4-4;1.0 kV (power line), 0.5 kV (signal line)
• conducted: IEc 61000-4-6; 3 V
environmental regulatory Compliance
• EU 2002/95/Ec RoHS (with lead exemption)
• EU 2002/91/Ec WEEE
warranty
• 1-year hardware
• 90-day software
mounting options
• 19 Universal EIa 310 (telco) Rack or tabletop
system max
@ 100 VaC
@ 200 VaC
@ -48 VDC
Current
Amps
Power
Watts
Thermal
Output
BtU/Hr
Current
Amps
Power
Watts
Thermal
Output
BtU/Hr
Current
Amps
Power
Watts
Thermal
Output
BtU/Hr
BigIron RX-32
N/a
N/a
N/a
57
11,353
38,746
237
11,353
38,746
BigIron RX-16
49
4,905
16,741
24
4,905
16,741
102
4,905
16,741
BigIron RX-8
24
2,417
8,249
12
2,417
8,249
50
2,417
8,249
BigIron RX-4
12
1,217
4,155
6
1,217
4,155
25
1,217
4,155
broCaDe bigiron rX series system sPeCiFiCations