beautypg.com

Esl600 series operation manual, Important - installation and safety – HMC Electronics CESL611-ESD Delta Regis Brushless Electric Screwdriver User Manual

Page 2

background image

ESL600 Series

Operation Manual

Important - Installation and Safety

Please read and understand the operation manual and follow all safety and operation instructions.

1.

Use these products in a suitable dry, indoor location. Do not use the tools and controllers in damp,

2.

wet or high temperature environments. Do not use in the presence of flammable liquids or gases.

Ensure that the controller has proper ventilation. Do not expose the tools and controllers to areas

3.

subject to airborne contaminants (eg. dust, metal filings).

Use only a properly grounded electrical outlet of the correct supply voltage to power the screwdriver

4.

co ntroller. Ensure that the supply outlet is overload protected and of sufficient amperage capacity.

Use only the correct plug for the controller and outlet. Hold the plug of the power cord when

5.

connecting or disconnecting. Do not pull on the cable.

Do not expose the cable, tool or controller to oil, chemicals, or heat. Ensure that the cable is routed

6.

and used in such a manner as to not be subject to sharp objects that may abrade or cut the cable.

Locate the controller in a suitable, safe location on a steady surface. Do not place in a high location

7.

where there may be a risk of it falling. Secure the controller in position to prevent possible movement

caused by pulling on the power or tool cables.

Do not cover the controller or stack any objects on top of or near the controller. Ensure that adequate

8.

clearance and ventilation is provided around the perimeter of the controller.

The ‘BECT6’ series controllers are for use exclusively with Delta Regis brand ‘ESL6’ series

9.

screwdrivers as specified on the following pages. Use of the controller (or screwdriver) with any

other screwdriver (or controller) may result in malfunction, damage, or injury.

In the event that the controller is overloaded beyond the maximum current rating, an internal fuse will

10.

disrupt power. Should the controller stop functioning, or exhibit abnormal or intermittent operation,

please discontinue use immediately and send the controller to an authorized service centre for

troubleshooting and repair.

Excessive duty cycle will cause the tool and/or controller to overheat. If this occurs, discontinue use

11.

until cooled down and reduce cycle rate. As a general rule, do not exceed 10-15 screws/minute.

The ‘ESL6’ series screwdrivers incorporate a protection circuit which stops the electric screwdriver

12.

if the tool is switched from forward to reverse while running. Should this happen, the operator must

release the tool trigger and restart the fastening cycle.

Turn the main power switch off when the controller is not being used. Unplug the controller if it is not

13.

being used on a regular basis.

Do not attempt to disassemble or repair the screwdriver or controller. Repairs should only be

14.

performed by qualified technicians properly trained in the safe operation, troubleshooting, and repair

of these devices. Please consult Delta Regis for the location of the nearest service depot.

Use only the factory specified Delta Regis brand replacement parts and accessories with these tools

15.

and controllers.

Any damage to the tool and/or controller resulting from misuse, abuse, or failure to follow these

16.

guidelines will void the limited product warranty.

Warning - Failure to understand and follow proper installation guidelines, safety requirements,

and operating instructions may result in malfunction, component damage, property damage,

shock hazard, fire hazard, injury or death.

Grounding - This controller (and AC power cord) is equipped with a 3-prong electrical receptacle/plug

with ground pin. The controller must be connected to a properly grounded AC electrical outlet. Do not

attempt to use this controller without a properly functioning ground connection. Never connect a live

circuit to the ground pin or internal yellow-green ground wire.

Page 2

Documentation Provided By HMC Electronics

33 Springdale Ave. Canton, MA 02021

http://www.hmcelectronics.com

(800) 482-4440

This manual is related to the following products: