Chapter 4 Additional Information
Specifications
System
Frequency range: 2400~2483MHz
Remote range: Approx. 100 feet (30 meters) indoors, 328 feet (100 meters)
outdoors
Operating voltage: Remote control: 2.4V~3.3V, Laser: 2.6V~3.3V
Power: AAA batteries * 2
Very low power consumption: Normal operation <10mA
Laser operation < 20mA
Sleep < 10uA
Output power: Under 1mW
Physical Dimensions
Size: Tx: 130(l) x 38.2(w) x 23.5(h) mm. Rx: 49(l) x 16(w) x 3.5(h) mm
Weight: Approx. Tx: 60 grams (include batteries)
Rx: 2.6 grams
Environmental Requirements
Temperature:
Operating: 0℃(32℉)~60℃(140℉)
Non-operation: -10℃(14℉)~65℃(149℉)
Humidity(non-condensing):
Operating: 10%~85% RH
Non-operating: 10%~95% RH
Laser
Semiconductor laser(λ= 650 nm), emission duration: continuous
Laser output power: Max.0.95 mW
Note: Design and specifications are subject to change without notice.
Care and Maintenance
For cleaning, you are advised to use a soft, slightly moistened cloth.
Avoid using solvents or abrasive substances.
Do not open the presenter: for maintenance, consult qualified staff only.