3. INSTALLATION

Your BEHRINGER MULTICOM PRO was carefully packed in the factory and the packaging was designed to

protect the unit from rough handling. Nevertheless, we recommend that you carefully examine the packaging

and ist contents for any signs of physical damage, which may have occurred in transit.
Please also take the time to complete and return the warranty card within 14 days of the date of purchase,

otherwise you will lose the right to the extended warranty. Or simply use our online registration under

www.behringer.com.

+

If the unit is damaged, please do not return it to us, but notify your dealer and the shipping

company immediately, otherwise claims for damage or replacement may not be granted.

Shipping claims must be made by the consignee.

3.1 Rack Mounting

The BEHRINGER MULTICOM PRO fits into one standard 19" rack unit of space (1 3/4"). Please allow at least

an additional 4" depth for the connectors on the back panel. Be sure that there is enough air space around the

unit for cooling and please do not place the MULTICOM PRO on high temperature devices such as power

amplifiers etc. to avoid overheating.

3.2 Mains Voltage

Before you connect your MULTICOM PRO to the mains, please make sure that your local voltage

matches the voltage required by the unit! The fuse holder on the female mains connector has 3 triangular

markers, with two of these triangles opposing each other. Your MULTICOM PRO is set to the operating voltage

printed next to these markers, and can be set to another voltage by turning the fuse holder by 180°. CAUTION:

this instruction does not apply to export models exclusively designed, e.g. for 115 V operation!

3.3 Audio Connections

The audio inputs and outputs on the BEHRINGER MULTICOM PRO are fully balanced. If possible, connect the

unit to other devices in a balanced configuration to allow for maximum interference immunity.

+

Please ensure that only qualified persons install and operate the VIRTUALIZER. During instal-

lation and operation the user must have sufficient electrical contact to earth. Electrostatic

charges might affect the operation of the MULTICOM PRO!

1

2

3

2

1

3

Pin 1

Cable

Input

Output

Pin 2 = (+) Signal

Positive

Pin 3 = (-) Signal

Shield

(+) Signal + Hum

(-) Signal + Hum

Negative

(+)Hum + Signal

(-)Hum + Signal

2 x Signal

Ground

RFI and Hum

= Signal + 6 dB

Fig. 3.1: Compensation of interference with balanced connections

3. INSTALLATION