beautypg.com

Gast SDR6 User Manual

Page 6

background image

RECOMMENDED ACCESSORIES

The following diagrams are only suggested configurations for these accessories. These accessory configurations may

vary depending upon a particular unitʼs application.

For Model Number

R3, R4, R5

R4, R4H,

R4H, R4M,

R4M, R6,

R4P, R5

R5, R6,

R6P, R6PP,

R6P, R6PS,

R7, R7P,

R7S, R9,

R9S

Part Number

RMS160

RMS200

RMS300

RMS400

CFM capacity

160

200

300

400

Liquid capacity (gal.)

10

19

19

40

Diameter (A)

14.8”

19.7”

19.7”

24”

Dimension (B)

37.5”

35”

35”

44”

NPT outlet (C)

2”

2”

2.5”

3”

Inlet diameter (D)

2”

2”

2.5”

3”

Dimension (E)

7.5”

7.5”

7.5”

9.7”

Dimension (F)

26.6”

26.6”

26.6”

29”

Model Number

R1, R2

R3

R4, R5, SDR4,

R6, R6P, SDR6P,

R7, R7S

SDR4, R4P

SDR6, R6PS

Part Number

AH326B

AH326C

AH326D

AH326F

AH326G

Dimension (A)

3.57”

4.19”

4.50”

5.25”

8.00”

Dimension (B)

2.32”

2.69”

2.94”

3.82”

5.07”

Dimension (C)

1.00” NPT

1.25” NPT

1.50” NPT

2.00” NPT

2.50” NPT

MOISTURE SEPARATOR (FOR VACUUM)
This moisture separator removes liquids from the gas stream in a vacuum process.

This helps protect the blower from corrosion and the build up of mineral deposits.

HORIZONTAL SWING TYPE CHECK VALVE
This check valve prevents backwash of fluids from entering the blower and air back-streaming.

The check valve can be mounted to discharge or inlet either vertically or horizontally. The check

valve will open with 3” of water pressure or vacuum.

Maximum vacuum allowed: 22” Hg.

X

Explosion-proof, high level

float switch AJ213 (optional).

6