Start Up

Operate blower for an hour and then check:

1. Ambient temperature – Check room and

discharge air temperatures. Increased room

temperatures may require stronger ventilation

especially for larger blowers. Exhaust air

should not exceed 215ºF (102ºC) for all

blowers less than 3.5 Hp. Exhaust air should

not exceed 275ºF (135ºC) for all blowers

above 3.5 Hp.

2. Working pressure and vacuum values – Adjust

relief valve pressure or vacuum setting, if

needed.

It is your responsibility to operate this product at

recommended pressures or vacuum duties and

room ambient temperatures.. Do not throttle

discharge or suction pipe to reducer capacity.

Throttle will increase differential pressure causing

increasing power absorption and working

temperatures.

OPERATION

Injury Hazard

Install proper safety guards as needed to prevent
any close contact with blower suction area.

Keep fingers and objects away from openings and
rotating parts.

Product surfaces become very hot during operation,
allow product surfaces to cool before handling.

Air stream from product may contain solid or liquid
material that can result in eye or skin damage,
wear proper eye protection.

Wear hearing protection. Sound level from some
models may exceed 85 dBA.

Failure to follow these instructions can result in
burns, eye injury or other serious injury.

WARNING

MAINTENANCE

Electrical Shock Hazard

Disconnect electrical power supply cord to drive

motor before performing maintenance on this

product.
Some motors are thermally protected and will

automatically re-start when protector resets.
If product is hard wired into system, disconnect

electrical power at the circuit breaker or fuse box

before performing maintenance on this product.
Failure to follow these instructions can result in

death, fire or electrical shock.

WARNING

It is your responsibility to regularly inspect and

make necessary repairs to this product in order to

maintain proper operation. Make sure that pressure

and vacuum is released from product before

starting maintenance.

Injury Hazard

Product surfaces become very hot during operation,
allow product surfaces to cool before handling.

Air stream from product may contain solid or liquid
material that can result in eye or skin damage,
wear proper eye protection.

Failure to follow these instructions can result in
burns, eye injury or other serious injury.

WARNING

The separate drive electric motor and blower need

periodic cleaning to remove accumulated dust and dirt.

If they are not cleaned, this can result in excessive

vibration, an increase in temperature or can reduce the

service life of the system.

Check filter elements and clean motor and blower after

first 500 hours of operation. Replace filter elements.

This one procedure will help assure the productʼs

performance and service life.

An increase in the differential pressure across an inlet

filter indicates its getting clogged. Clean the inlet air

filter as often as needed, blowing down against the

current to clean it. A dirty filter cartridge causes a high

intake resistance resulting in an increase of differential

pressure, absorbed power and working temperature.

Failure to clean replace these filters will result in

excessive pressure drop, a reduction in system air flow

and the blower will run hotter.

Power must be de-energized and disconnected

from the drive motor before servicing. Be sure all

rotating parts have stopped, electrical shock or

severe cuts can result if hazard is ignored.

WARNING