Important – Garland SH DU IN 10000 (2x5000 / 10kW) INDUCTION BUILT-IN LINE DUAL-ZONE COOKERS User Manual
Page 14
Installation
RTCSmp Induction Built-In Line Dual Zone Cookers
14
Part # 4532285 Rev 4 (4/29/14)
4.3.3.2
Installation Steps
1. Cut-out dimension: 9.25” x 6.50” (235mm x 165mm).
2. Mount the Air Filter Holder onto the cabinet. Then connect the Duct Holder and the Flex Duct.
NOTE: The maximum length of the air duct must not exceed 96”(244cm).
3. The Air Filter Holder is fitted with a removable Air Intake Filter. Ensure the filter is visible and easily
accessible. Please label the Air Filter or its location for the kitchen staff.
IMPORTANT
The Air Intake Filter (Grease Filter) should be in visible view, easily accessible, and
labeled. A blocked filter can cause electronic damage to the induction unit. Refer
to chapter 7 Cleaning.
4. To allow hot exhaust air to escape, install in the cabinet an air exhaust opening such as a louvered air
duct, which must be at least 1.5 times or greater than the air intake opening. Depending on the air path
and the amount of natural air movement, it is highly recommended that an exhaust fan be installed into
the cabinet to pull hot air out.
IMPORTANT
Failure to provide adequate ventilation for the unit will result in the unit
overheating, nuisance shutdown, and potential failure of the unit.
9" [288.6 mm]
8 3/16" [208 mm]
11" [279.4mm]
10 3/16" [258.8mm]
3/16" [4.5mm]
Cut-Out:
9.25" x 6.50"
[235 x 165 mm]
(4x)
FRONT
BACK