Flex ISO III Roof Insulation User Manual

Acfoam, Iii insulation, Data sheet

background image

(770) 952-1442 • ATLAS ROOFING CORPORATION • 2000 RIVEREDGE PARKWAY, SUITE 800 • ATLANTA, GA • 30328 • www.AtlasRoofing.com

Data Sheet

Other than the aforementioned representations and descriptions, Atlas Roofing Corporation (hereafter, “Seller”) makes no other representations or warranties as to the insulation sold herein. The Seller disclaims all other warranties,
express or implied, including the warranty of merchantability and the warranty of fitness for a particular purpose. Seller does, however, have a limited warranty as to the LTTR-Value of the insulation, the terms of which are available
upon request from the Seller. Seller shall not be liable for any incidental or consequential damages including but not limited to the cost of installation, removal, repair or replacement of this product. Buyer’s remedies shall be limited
exclusively to, at Seller’s option, the repayment of the purchase price or resupply of product manufactured by Atlas in a quantity equal to that of the nonconforming product. Atlas distributors, agents, salespersons or other independent
representatives have no authority to waive or alter the above limitation of liability and remedies.

Physical ProPerties

thermal Data

ProPerty

test methoD

results

Dimensional Stability

ASTM D2126

< 2%

Compressive Strength

ASTM D1621

20 psi (140 kPa) or

25 psi (172 kPa)

Water Absorption

ASTM C209 & D2842

< 1.5%, < 3.5%

Water Vapor Transmission

ASTM E96

< 4.0 perm (228.8ng/(Pa•s•m

2

))

Product Density

ASTM D1622

Nominal 2.0 pcf (32.04 kg/m

3

)

Flame Spread

ASTM E84 (10 min.)

1

40-60

Smoke Development

ASTM E84 (10 min.)

1

50-170

Tensile Strength

ASTM D1623

> 730 psf (35 kPa)

Service Temperature

-

-100° to + 250°F

lttr Value

thickness

2

rsi

Flute sPanability

in

mm

in

mm

5.6

1.0

25.4

0.99

2.625

66.68

8.5

1.5

38.1

1.49

4.375

111.13

11.4

2.0

50.8

2.01

4.375

111.13

14.4

2.5

63.5

2.53

4.375

111.13

17.4

*3.0

76.2

3.06

4.375

111.13

20.5

*3.5

88.9

3.61

4.375

111.13

23.6

*4.0

101.6

4.16

4.375

111.13

1

Numerical ratings are not intended to reflect performance under actual fire conditions. Flame spread index of 75
and smoke development
450 meet code requirements for foam plastic roof insulation. Codes exempt foam plastic
insulation when used in FM 4450 or UL 1256. Physical properties listed above are presented as typical average
values as determined by accepted ASTM test methods and are subject to normal manufacturing variation.

• ASTM C1289, Type II, Class 2, Grade 2 (20 psi) or Grade 3 (25 psi)

• CAN/ULC-S704, Type 2, Class 3 or Type 3, Class 3

• CCMC No. 12464-L

• UL Certified for Canada – Insulated Roof Deck Assemblies Construction

No. C38 and 52, Meet CAN/ULC-S126, CAN/ULC-S101 and CAN/ULC-S107

• UL Standard 1256 Classification – Construction No. 120, 123 & 292

• UL Standard 790 (ASTM E108) Roofing Systems Classification

• UL Standard 263 (ASTM E119) Fire Resistance Classification

• UL Standard 1897 Uplift Resistance

• FM Standard 4450/4470 Approved

Refer to FM Approvals

®

RoofNav for Specific System Details

• IBC Chapter 26 & NBC Sections on Foam Insulation

• California State Insulation Quality Standards and Title 25 Foam

Flammability Criteria (License #TC 1231)

• Miami-Dade County Approved

• State of Florida Product Approval (FL6796)

LTTR (long term thermal resistance) values were determined in accordance with CAN/ULC-S770-09. Test samples
were third-party selected and tested by an accredited material testing laboratory. The LTTR results were reviewed by
FM Global and certified by the PIMA Quality Mark Program.

2

RSI is the metric expression of R-value (m

2

K/W).

*Multi-layer application is strongly recommended when the total insulation thickness exceeds 2.7"

ACFoAm

®

-III InsulAtIon

DescriPtion:

aDVantages:

aPPlication:

installation:

Closed-cell polyisocyanurate (polyiso) foam core integrally bonded to inorganic coated glass facers. ACFoam

®

-III is offered in a variety of thicknesses,

providing long-term thermal resistance (LTTR) values from 5.6 to 23.6. Available in 4ft x 4ft (1220mm x 1220mm) and 4ft x 8ft (1220mm x 2440mm)
panels. Manufactured in accordance with

ASTM C1289, Type II, Class 2, Grade 2 (20 psi) or Grade 3 (25 psi) and CAN/ULC-S704 Type 2, Class 3

or Type 3, Class 3.

When using ACFoam

®

-III in adhered systems, field testing has confirmed significantly more efficient use of solvent-based adhesives than with organic

faced insulations. Adhesive application rates vary by manufacturer. Check adhesive manufacturer’s recommendation for application rates. Manufactured
using CFC-, HCFC- and HFC-free foam blowing technology with zero ozone depletion potential (ODP) and virtually no (negligible) global warming
potential (GWP). Recognized by the GREENGUARD Environmental Institute as resistant or highly resistant to mold growth based on independent
testing using GREENGUARD Test Method GGTM.P040 (ASTM D6329) for microbial resistance. ACFoam

®

-III contains between 6.2% and 10.9%

recycled materials by weight.

Manufactured and tested for use in new and re-roofing applications. ACFoam

®

-III is used in built-up (BUR), modified bitumen, metal, ballasted single-

ply, mechanically attached single-ply and adhered single-ply roofing systems. These roofing systems depend on proper installation for successful
performance. Refer to FM Approvals

®

RoofNav and UL Online Certifications Directory for additional application details.

ACFoam

®

-III shall be kept dry before, during and after installation. This product will burn if exposed to an ignition source of sufficient heat and intensity.

Do not apply flame directly to ACFoam

®

-III insulation. Refer to PIMA Technical Bulletin 109: Storage and Handling Recommendations for Polyiso Roof

Insulation.

An offset or staggered multi-layer application of ACFoam

®

is strongly recommended when the total insulation thickness exceeds

2.7" (Atlas Technical Bulletin: TB-5). Typical field fastening requirements can be obtained from membrane system manufacturer or FM Global
Property Loss Prevention Data Sheets 1-29.

Prior to installation, Atlas Roofing Corporation recommends that you consult your local building codes, contract documents, professional engineer, FM
Global, Miami-Dade County and membrane manufacturer for additional installation guidelines as well as design enhancements.

© Copyright 2014, Atlas Roofing Corporation 01/14 ATL-132264-00