beautypg.com

Flex MF/R 60 PVC User Manual

Page 2

background image

Flex Membrane International Corp. 2670 Leiscz’s Bridge Road, Suite 400, Leesport, PA 19533

Tel: (610) 916-9600 Fax: (610) 916-9601 www.FlexRoofingSystems.com

Page 2

PHYSICAL PROPERTIES

Property

Test Procedure

Specification

Color

White, Gray, Tan

Thickness

ASTM D751

.060” nominal

Roll Size

60” x 80’

78” x 80’

120” x 80’

Weight

6.55 oz./ft²

Breaking Strength

ASTM D751 256 x 242

(minimum, lbf/in.)
Seam Strength

ASTM D751

297 lbf

Elongation @ Break

ASTM D751

57% x 54%

Heat Aging

ASTM D3045

>90%

Tear Strength min. lbf.

ASTM D751

99 x 70

Low Temperature Bend

ASTM D2136

PASS (-40ºF)

Static Puncture Resistance

ASTM D5602 PASS @ 33 lbs.

Dynamic Puncture Resistance

ASTM D5635

PASS @ 20 J

Dimensional Change

ASTM D-1204

0.25%

(maximum %)

(@ 176º F, 6 hours)

Water Immersion

ASTM D-570

1.96%

Accelerated Weathering

ASTM G-155

PASS

Solar Reflectivity

ASTM C1549 .82 (white)

Emissivity

ASTM C1371

.91 (white)

SRI

ASTM E1980

109


Flex MF/R PVC membrane is thermoplastic in nature and exceeds the requirements of ASTM D4434
standard specification for poly (vinyl chloride) sheet roofing.

WARRANTY

The Flex MF/R 60 PVC Roofing Membrane may receive the manufacturer's standard five (5) year, ten
(10) year, fifteen (15) year or twenty (20) year guarantee of watertightness.