Compressor operation overload protection reset, Warning – Briggs & Stratton Proseries User Manual
Page 11
11
Compressor Operation
You do not have to use the maximum operating pressure at
all times because the air tool being used often requires less
pressure. Here are general guidelines for setting pressure.
1. With air compressor connected to proper power and
turned ON, attach desired air tool or accessory to quick
connect fitting. Use recommended air hose and quick
connect fitting.
2. Activate air tool and turn pressure control knob
clockwise to increase outlet pressure.
3. Observe outlet pressure gauge and adjust pressure to
recommended setting of accessory tool.
NOTE: You must adjust outlet air pressure while tool is
operating or activated.
4. Use lock ring on pressure control to lock in selected
pressure setting by tightening it against pressure
control knob.
5. Always operate this unit on a level surface to avoid
lubrication problems.
Overload Protection Reset
This compressor is equipped with an overload protection
feature that protects the motor. If the circuit breaker trips,
wait 15 minutes for the motor to cool. Then push the RESET
button (A) located on the motor shroud.
Also see Troubleshooting for more information.
Observe these safety precautions when operating air
compressor:
WARNING
Exceeding pressure rating of attachments or
inflatables can cause severe injury and / or
property damage.
• DO NOT adjust pressure greater than maximum rating of
attachments or inflatables.
A
WARNING
Operating air compressor and tubing are HOT
and can cause burns.
• DO NOT touch compressor or tubing.
• Allow compressor to cool before servicing.
WARNING
Compressed air is not breathable and can cause
bodily injury.
Some paints or solvents may be harmful if
inhaled or ingested, causing severe nausea,
fainting or poisoning.
• DO NOT use compressed air for breathing.
• Always use NIOSH respirator approved for your application
when spraying.
• Read all instructions with respirator so you are certain it will
provide necessary protection against inhaling harmful vapors.
WARNING
Compressed air stream from hose or tank drain
can cause soft tissue damage to exposed skin
and can propel objects leading to severe injury
and / or property damage.
• DO NOT direct air stream at self or others.
• Always wear ANSI Z87.1 approved safety glasses with side
shields.
WARNING
Compressor can start any time when plugged in.
• STAY CLEAR
• Disconnect from power source and drain pressure from tank
when not in use or before servicing.
WARNING
Contact with compressor or its cord can cause
electric shock or burn.
Compressor must be grounded.
• DO NOT use grounding adapters. Inspect cord before each use.
• DO NOT operate with protective covers / guards removed or
damaged.
• DO NOT operate in wet conditions. Store unit indoors.
• Disconnect from power source and drain pressure from tank
when not in use or before servicing.