Usea0-1800RPMvariablespeedcordedor18Vcordlessnon-impactdrill.
•
Installfastenerinacontinuousdriveuntilheadisslightlybelowflush.
Installtwoscrewsateveryjoist.
•
Whenfasteningwithin1
•
1
⁄
2
"fromtheendofaboard,followthecommon
practiceofpredrillingapilotholeusinga
1
⁄
8
"bit.Thiswillpreventtheboard
fromsplitting.
Installscrewsnocloserthan
•
3
⁄
4
"fromedgeofboard.
DonotuseTrapEaseIIwhenattachingcompositesover“fixed”surfaces:
•
sleepersystems,roofdecks,solidwoodsurfaces(i.e.fascia,handrails)or
metaljoists.
TrapEaseStainlessSteelscrewsarerecommendedinthesefixedsurface
•
conditionsorwhendeckingisbeingappliedoverrestrictedairspace(less
than12"ofclearancebelowthejoistson3sides).
Forsolidwooddecking,consultourwebsitefortheproperdeckscrew.
•
Warrantymaybecomevoidiftheseinstallationinstructionsorthoseofthe
deckingmanufacturer/supplierarenotfollowed.
GUARANTEED CORROSION RESISTANCE
TrapEaseIIisguaranteednottorustorstreakincompositedeckingforthe
lifeoftheprojectwheninstalledcorrectly.Thefastenerhasalsobeentested
andapprovedforfasteningcompositedeckingtopressuretreatedwoodsuch
asACQandCA-B.Aguaranteeregardingthiscanbefoundon
www.FastenMaster.com.UseTrapEaseIIStainlessSteelCompositeDeckScrews
whentheapplicationiswithin1,000feetofsaltwaterorwhende-icingsalts
willbeincontactwithdecking.
DEEP #1 SQUARE DRIVE
REDUCES CAM OUT
COLOR COATED TO
MATCH DECKING
GUARANTEED CORROSION
RESISTANT COATING.
ACQ APPROVED
THREAD DESIGN ENGINEERED
FOR SMOOTH FINISH
Part Number
Color Code
Screw Length
Quantity
per Box
Sq. Ft. of
Deck Surface
FMTR2-234-350GY
Gray
2¾"
350
100
FMTR2-234-350BR
Brown
2¾"
350
100
FMTR2-234-350DR
Dark Redwood
2¾"
350
100
FMTR2-234-350DB
Dark Brown
2¾"
350
100
FMTR2-234-1750GY
Gray
2¾"
1750
500
FMTR2-234-1750BR
Brown
2¾"
1750
500
FMTR2-234-1750DR
Dark Redwood
2¾"
1750
500
FMTR2-234-1750DB
Dark Brown
2¾"
1750
500
FMTR2-003-350GY
Gray
3"
350
100
FMTR2-003-350BR
Brown
3"
350
100
FMTR2-003-350DR
Dark Redwood
3"
350
100
FMTR2-003-350DB
Dark Brown
3"
350
100
FMTR2-003-1750GY
Gray
3"
1750
500
FMTR2-003-1750BR
Brown
3"
1750
500
FMTR2-003-1750DR
Dark Redwood
3"
1750
500
FMTR2-003-1750DB
Dark Brown
3"
1750
500
*Based on a fastening pattern of 2 screws per joist, spaced every 16”, into standard 6” wide decking
FM09186-5M-AML FMTR2SHEET
FASTENMASTER, INC., 153 BOWLES ROAD, AGAWAM, MA 01001
800.518.3569
WWW.FASTENMASTER.COM
FastenMaster
®
, and TrapEase
®
II are trademarks of OMG, Inc. Copyright ©2009 OMG, Inc. All rights reserved.
INSTALLATION PROCEDURE
PRODUCT FEATURES