Temperature – Despatch LFD Series with Protocol Plus User Manual
Page 11

3
Temperature
Model
LFD 1-42
LFD 2-11
LFD 2-24
Time to Temperature
25°C - 100°C
(approximate minutes with
25°C - 200°C
no load)
25°C - 343°C
4
10
35
4
10
30
2
10
40
Recovery Time Door Open 1 Min.
100°C
(approximate minutes with
200°C
no load)
343°C
<1
2
4
<1
3
8
<1
3
7
Temperature Uniformity at
100°C*
200°C*
343°C*
±1°C
±2°C
±4°C
±1°C
±2°C
±4°C
±1°C
±2°C
±4°C
Minimum Operating Temperature
dampers open
(Approximate w/20 C ambient)
dampers closed
40°C
50°C
30°C
40°C
30°C
55°C
Control Stability
±0.3°C
±0.3°C
±0.3°C
Repeatability
±0.5°C
±0.5°C
±0.5°C
Cooldown Time
343 - 50°C dampers open
(approximate
343 - 75°C dampers closed
minutes with no load)
46
110
40
120
27
85
* Figures are based on actual tests in an empty oven. Uniformity can vary slightly