CAUTION: PRIOR TO INSTALLATION,
PLEASE READ IMPORTANT SAFETY INSTRUCTIONS THOROUGHLY

This transformer has an output rating of 120 Watts, 12 Volts AC. The maximum load (combined

wattage of all fixtures) connected to this transformer should not exceed 120 Watts.

MOUNTING THE TRANSFORMER

Using fasteners suitable for your mounting surface, mount no less than 20 inches above the

ground. Do not mount transformers in heavily shaded areas or where excessive ambient light will

affect the photocell. The transformer should be mounted outdoors and connected to a grounded

GFCI outdoor electrical outlet.

CONNECTING THE LOW VOLTAGE CABLE

Strip 3/8” of insulation off the ends of the low voltage cable. Insert stripped ends under pressure

plates. Tighten pressure plates securely onto the bare wire. (Fig. 2)

OPERATION INSTRUCTIONS

Note: The timer settings for powering ON the transformer are controlled by a photocell. (Fig. 1)

Photocells are designed to recognize daylight and darkness. The photocell will automatically turn

power on at dusk and supply power for the designated time setting you select.

Open the clear cover on the front of unit. Rotate the timer rotary control switch to one of the six

positions. (Fig. 1 and 3)

“ON” turns the transformer ON for 24 hour operation.

“OFF” turns the transformer OFF.

“Auto” sets the transformer for “Dusk to Dawn” operation

(turns power ON at dusk and turns power OFF at dawn).

“4H” turns transformer ON at dusk for 4 hours operation.

“6H” turns transformer ON at dusk for 6 hours operation.

“8H” turns transformer ON at dusk for 8 hours operation.

CIRCUIT BREAKER

The transformer includes a resetable circuit breaker to protect against short circuits in the second-

ary field wiring. (Fig. 1) Should power turn off to the secondary unexpectedly, check for shorts in

the landscape wire and fixtures before resetting the circuit breaker.

The diagrams and instructions in this brochure are for illustration purposes only and are not meant to replace a licensed professional. Any construction or use of the product must be in

accordance with all local zoning and/or building codes. The consumer assumes all risks and liability associated with the construction or use of this product. The consumer or contractor

should take all necessary steps to ensure the safety of everyone involved in the project, including, but not limited to, wearing the appropriate safety equipment. EXCEPT AS CONTAINED

IN THE WRITTEN LIMITED WARRANTY, THE WARRANTOR DOES NOT PROVIDE ANY OTHER WARRANTY, EITHER EXPRESS OR IMPLIED, AND SHALL NOT BE LIABLE FOR ANY DAMAGES,

INCLUDING CONSEQUENTIAL DAMAGES.

©2012 Universal Forest Products, Inc.

6832 LVTRAN 120W_4/12

LOW VOLTAGE LIGHTING POWER SUPPLY

120W, 12 Volt AC outdoor loW VoltAge trAnsformer for lAndsCApe lighting fixtures
MODEL NO.: DA-120-12W-1, ITEM NO.: 141769

IMPORTANT SAFETY INSTRUCTIONS:

SAVE THESE INSTRUCTIONS: This manual contains important safety and operating instructions for power units.

When using electrical products, basic precautions should always be practiced including the following:
1. Read and follow all instructions that are on the product or provided with the product.
2. For a cord-connected or direct plug-in power unit, do not use an extension cord.
3. Reference the National Electrical Code, ANSI/NFPA 70, specifically for the installation of wiring and clearances from power and lighting

conductors.

4. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including

fire-rated construction.

5. For a cord-connected or direct plug-in power unit, do not install or use within 10 feet of a pool.
6. For a direct plug-in or cord-connected power unit marked:

WARNING: Risk of Electric Shock. When used outdoors, install only to a covered Class A GFCI protected receptacle that is weatherproof with

the power unit connected to the receptacle. If one is not provided, contact a qualified electrician for proper installation. Ensure that the power

unit and cord do not interfere with completely closing the receptacle cover.

7. WARNING: Risk of Fire. Installation involves special wiring methods to run wiring through a building structure. Consult a qualified electrician.

Fig. 3

Fig. 2

Fig. 1

Photocell

Timer rotary

control switch

Circuit

Breaker