beautypg.com

Warning – New Buck Corporation 74 User Manual

Page 12

background image

SECTION III

PRE-FAB INSERT INSTALLATION


The Model 74 has been tested with the following UL listed manufactured Pre-Fab Fireplaces:

Heatilator Security
Tempco Preway
Marco

FMI

Woodside

Majestic


The Model 74 will fit any of the models that are large enough to accept them.

NOTE: A full chimney liner is required in a Zero Clearance or pre-fab fireplace.

NOTE: The ash lip, smoke baffle, and smoke shelf may be removed if necessary to provide
room for these models. Any other alteration to the unit will void ALL NBC manufacturer's
responsibility and liability. The warning label below must be attached to the back of the fire -
place.

Except for the “NOTES” above, please follow the instructions for Masonry Insert Installation
including Minimum Clearances for stove and floor protector in Section II.



















WARNING:

This fireplace must be

restored to its original condition for safe use, if
the fireplace insert is removed.

10