Page 25

36102 090203

FIG. 16 VOLTAGE SELECTOR SWITCH

P2759.40

White/Violet to Tank Heater

Blue to Tank Heater

White to Terminal Block

FIG. 17 VOLTAGE SELECTOR

SWITCH TERMINALS

SERVICE (cont.)
VOLTAGE SELECTOR SWITCH -

DV models only

P2504

Location:

The voltage selector switch is located on the

component mounting bracket behind the front
access panel.

Test Procedure:

1. Disconnect the brewer from the power source.
2. Disconnect the white and blue wires from the

selector switch. With the selector switch in the
120V position, check for continuity between the
two empty terminals of the switch.

If continuity is present as described, reconnect the
white wire and continue to Step 3.
If continuity is not present as described, replace the
voltage selector switch.

3. With the selector switch in the 120/208-240V

position, disconnect the white/violet wire from the
selector switch. check for continuity between the
two empty terminals.

If continuity is present as described, the voltage selec-
tor switch is operating properly.

If continuity is not present as described, replace the
voltage selector switch.

Removal and Replacement:
1. Disconnect the brewer from the power source.
2. Disconnect the three wires from the selector switch.
3. Remove the switch mounting nut from the under

side of component mounting bracket; remove
switch from bracket.

4. Install new switch in component mounting bracket

and secure with mounting nut.

5. Refer to FIG. 17 when reconnecting wires to the

switch.